(A) Each licensee or registrant shall make, or cause to be made, surveys of areas, including the subsurface, that:
(B) Notwithstanding the provisions in 105 CMR 120.263(A), records from surveys describing the location and amount of subsurface residual radioactivity identified at the site must be kept with records important for decommissioning, and such records must be retained in accordance with 105 CMR 120.125(C)(8), as applicable.
(C) The licensee or registrant shall ensure that instruments and equipment used for quantitative radiation measurements, for example, dose rate and effluent monitoring, are calibrated at intervals not to exceed 12 months for the radiation measured except when a more frequent interval is specified in another applicable section of 105 CMR 120.000 or license condition.
(D) All personnel dosimeters, except for direct and indirect reading pocket ionization chambers and those dosimeters used to measure the dose to any extremity, that require processing to determine the radiation dose and that are used by licensees and registrants to comply with 105 CMR 120.211, with other applicable provisions of 105 CMR 120.000, or with conditions specified in a license or certificate of registration, shall be processed and evaluated by a dosimetry processor:
(E) The licensee or registrant shall ensure that adequate precautions are taken to prevent a deceptive exposure of an individual monitoring device.