(A) The licensee shall perform inspection and maintenance checks that include, as a minimum, each of the following at the frequency specified in the license or license application:

(1) Operability of each aspect of the access control system required by 105 CMR 120.643.

(2) Functioning of the source position indicator required by 105 CMR 120.651(B).

(3) Operability of the radiation monitor for radioactive contamination in pool water required by 105 CMR 120.679(B) using a radiation check source, if applicable.

(4) Operability of the over-pool radiation monitor at underwater irradiators as required by 105 CMR 120.649(B).

(5) Operability of the product exit monitor required by 105 CMR 120.649(A).

(6) Operability of the emergency source return control required by 105 CMR 120.651(C).

(7) Leak-tightness of systems through which pool water circulates (visual inspection).

(8) Operability of the heat and smoke detectors and extinguisher system required by 105 CMR 120.647 (but without turning extinguishers on).

(9) Operability of the means of pool water replenishment required by 105 CMR 120.653(C).

(10) Operability of the indicators of high and low pool water levels required by 105 CMR 120.653(D).

(11) Operability of the intrusion alarm required by 105 CMR 120.643(I), if applicable.

(12) Functioning and wear of the system, mechanisms, and cables used to raise and lower sources.

(13) Condition of the barrier to prevent products from hitting the sources or source mechanism as required by 105 CMR 120.655.

(14) Amount of water added to the pool to determine if the pool is leaking.

(15) Electrical wiring on required safety systems for radiation damage.

(16) Pool water conductivity measurements and analysis as required by 105 CMR 120.683(B).

(B) Malfunctions and defects found during inspection and maintenance checks must be repaired without undue delay.

Disclaimer: These regulations may not be the most recent version. Massachusetts may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.