Code of Massachusetts Regulations
105 CMR - DEPARTMENT OF PUBLIC HEALTH
Title 105 CMR 120.000 - The Control of Radiation
RADIATION SAFETY REQUIREMENTS
Section 120.333 - Radiation Surveys and Survey Records
Current through Register 1531, September 27, 2024
(A) No radiographic operation shall be conducted unless at least one calibrated and operable radiation survey meter, as described in 105 CMR 120.314, is available and used at each site where radiographic exposures are made.
(B) A survey with a radiation survey instrument shall be made after each radiographic exposure to determine that the sealed source has been returned to its shielded position. The entire circumference of the radiographic exposure device, including the source guide tube and collimator if provided, shall be surveyed.
(C) A survey shall be made of the storage area as defined in 105 CMR 120.302 whenever a radiographic exposure device is being placed in storage.
(D) A physical radiation survey shall be made after each radiographic exposure using radiation machines to determine that the machine is "off."
(E)
(F) A survey with a radiation survey instrument shall be made to determine that the sealed source has been returned to its shielded position any time a radiographic exposure device is placed in storage. The entire circumference of the radiographic exposure device, including the source guide tube and collimator if provided, shall be surveyed.
(G) If a vehicle is to be used for storage of radioactive material, a vehicle survey shall be performed after securing radioactive material in the vehicle and before transport to ensure that radiation levels do not exceed the limits specified in 105 CMR 120.221(A) at the exterior surface of the vehicle.
(H) Surveys shall be performed on storage containers to ensure that radiation levels do not exceed the limits specified in 105 CMR 120.221(A). These surveys shall be performed initially with the maximum amount of radioactive material present in the storage location and thereafter at the time of the quarterly inventory and whenever storage conditions change.
(I) A survey meeting the requirements of 105 CMR 120.333(F) shall be performed on the radiographic exposure device and the source changer after every sealed source exchange.
(J) Records shall be kept of the surveys required by 105 CMR 120.333(E), (F), (G), (H), (I) and 105 CMR 120.318(A). These records shall be maintained for Agency inspection for five years after completion of the survey. If a survey was used to determine an individual's exposure due to loss of personnel monitoring data, the records of the survey shall be maintained until the Agency authorizes disposal.