Code of Maryland Regulations
Title 10 - MARYLAND DEPARTMENT OF HEALTH
Part 3
Subtitle 16 - HOUSING
Chapter 10.16.02 - Construction, Equipment, Sanitation, Operation, and Maintenance of Mobile Home Park
Section 10.16.02.05 - Service Building
Universal Citation: MD Code Reg 10.16.02.05
Current through Register Vol. 51, No. 19, September 20, 2024
A. Building and Equipment. If the park accommodates independent mobile homes exclusively, a service building may not be required; however, one is recommended for emergency use. Every park accommodating one or more dependent mobile homes shall be provided with at least one adequately equipped service building.
B. Required Facilities.
(1) The following facilities shall be minimum
for parks accommodating from one to ten dependent mobile homes:
(a) One flush-type toilet, one lavatory, and
a shower or bathtub with hot and cold running water for males; and
(b) One flush-type toilet, one lavatory, and
a shower or bathtub with hot and cold running water for females.
(2) One flush-type toilet bowl
receptacle shall be provided into which shall be emptied the contents of all
portable containers of human excrement. An adequate supply of hot and cold
water for cleaning the containers shall be provided. This equipment shall be in
a separate room of a service building with a single direct opening to the
outside. All plumbing of the service building shall comply with all applicable
plumbing codes.
(3) For those parks
accommodating more than ten dependent mobile homes, the following additional
fixtures shall be provided:
(a) One lavatory
and one shower or bathtub for each sex for every ten additional dependent
mobile homes or fraction of that;
(b) One flush-type toilet for females for
every ten additional dependent mobile homes or fraction of that;
(c) One flush-type toilet for males for every
additional 15 dependent mobile homes or fraction of that.
(4) Urinals may be substituted for not more
than one-third of the additional flush-type toilets required under §
B(3).
C. Location, Construction, Facilities.
(1) Where service
buildings are required they shall:
(a) Be
located 20 feet or more from any mobile home and not more than 200 feet from
any dependent mobile home.
(b) Be
of permanent construction, and adequately lighted.
(c) Be constructed of water and moisture
resistant material to permit frequent washing and cleaning. The floors of the
service building shall be of water impervious material other than wood and
shall slope to a drain connected to the sewerage system.
(d) Have adequate heating facilities to
maintain a minimum temperature of 70(F during cold weather, and supply adequate
hot water during the time of peak demands.
(e) Have all rooms well ventilated, with all
openings effectively screened against insects and rodents.
(f) Provide adequate compartments for each
bathtub or shower and water closet, and a sound resistant wall from floor to
ceiling to separate male and female toilet and bathing facilities.
(2) Laundry Facilities. Laundry
facilities shall be provided in the ratio of one laundry tray and one washing
machine, or an automatic washing machine, to every 30 mobile home spaces or
fraction of that. These facilities shall be provided in a separate room of a
service building or in a separate building.
Disclaimer: These regulations may not be the most recent version. Maryland may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google
Privacy Policy and
Terms of Service apply.