Current through Register Vol. 51, No. 19, September 20, 2024
The person-in-charge shall ensure that:
A. Potable water is:
(1) Obtained from a water supply system that
complies with Environment Article, Title 9, Annotated Code of Maryland, and
COMAR 26.04.04; and
(2) Meets the
standards of quality specified in Environment Article, Title 9, Annotated Code
of Maryland, and COMAR 26.04.01;
B. Non-potable water for non-culinary
purposes such as air conditioning or fire protection is used only if the system
complies with §H(3) of this regulation;
C. Except for a temporary food service
facility where water under pressure is not available, hot and cold running
water under pressure is provided:
(1) In all
areas where:
(a) Food is prepared;
and
(b) Equipment and utensils are
washed; and
(2) With
sufficient water capacity, pressure, and hot water generation and distribution
to meet peak demands throughout the facility;
D. Drinking water, if not dispensed through
the water supply system of the food service facility, is potable and stored in
a container that meets all applicable laws, ordinances, and
regulations;
E. Steam that contacts
food is free from deleterious or harmful matter that might adulterate
food;
F. All water-carried sewage
is disposed of by:
(1) A public sewerage
system; or
(2) An approved sewage
disposal system constructed and operated in conformance with applicable State
and local laws, ordinances, and regulations;
G. Where water-carried disposal methods are
not possible, non-water-carried sewage disposal facilities are utilized if:
(1) The method has been approved by the
approving authority as meeting State and local requirements; and
(2) The facilities are:
(a) In conformance with applicable State and
local laws, ordinances, and regulations; and
(b) Located outside and not attached to the
establishment;
H. Plumbing is sized, installed, and
maintained so that:
(1) The plumbing complies
with applicable State and local plumbing laws, ordinances, and
regulations;
(2) The potable water
supply system is:
(a) Installed in a manner
that prevents backflow or backsiphonage; and
(b) Not connected with a non-potable water
system in a manner that would allow non-potable water to be drawn or discharged
into the potable water supply system;
(3) The piping of a non-potable water system
is:
(a) Marked so that the piping is readily
distinguishable from piping that carries potable water, such as with
distinctive yellow-colored paint; and
(b) Not connected to equipment or other
outlets in the food preparation area;
(4) Indirect waste piping is provided to a:
(a) Food preparation or utensil washing
sink;
(b) Refrigerator
coil;
(c) Ice making
machine;
(d) Steam
kettle;
(e) Coffee urn or
brewer;
(f) Hot or cold drink
machine;
(g) Steam table;
(h) Potato peeler;
(i) Warewashing machine, unless:
(i) The machine is located within 5 feet of a
trapped floor drain; and
(ii) The
waste piping is connected directly to the inlet side of a floor drain trap
vented in conformance with applicable State and local laws, ordinances, and
regulations; and
(j)
Similar piece of equipment in which food, portable equipment, or utensils are
placed;
(5) Each
compartment of a multiple compartment sink is indirectly drained to a trapped
and vented plumbing receptor through an air gap that complies with State and
local laws, regulations, and ordinances:
(a)
From a separate pipe through the air gap and into the plumbing receptor;
or
(b) Through the air gap into a
single manifolded branch and into the plumbing receptor;
(6) Plumbing receptors receiving the
discharge of indirect waste pipes:
(a) Have a
shape and capacity that will prevent splashing or flooding; and
(b) Are accessible for cleaning and
inspection;
(7) Food
waste grinders are connected and trapped separately from other fixtures or sink
compartments;
(8) Floor drains
subject to evaporation have:
(a) A water seal
of at least 4 inches;
(b) Water fed
from a plumbing fixture that complies with State and local laws, regulations,
and ordinances; or
(c) An automatic
priming device that complies with State and local laws, regulations, and
ordinances;
(9) Floor
drains in storerooms, refrigerated rooms, walk-in coolers, or other locations
where food is stored, have indirect waste piping;
(10) Hand sinks in food preparation tables
and counters discharge through an air gap into a floor sink or receptor that is
trapped and vented; and
(11) Except
when required by building design, waste pipes and fixtures are:
(a) Not located over food storage,
preparation, or serving areas; and
(b) Where installed over food storage,
preparation, or serving areas, food is protected by one or more of the
following:
(i) Pipe joining methods that will
preclude leakage;
(ii) Using
wall-mounted fixtures;
(iii)
Limiting the number of pipe joints;
(iv) Pressure testing the piping;
(v) Thermally insulating pipes to prevent
condensation; and
(vi) Installing
integral seepage pans or pipe sleeves;
I. Toilet facilities are:
(1) Sufficient in number to serve the
facility;
(2) Conveniently
located;
(3) Accessible to
employees at all times;
(4) Except
as specified in Health-General Article, §21-325(b), Annotated Code of
Maryland, for facilities established after January 1, 1979, provided for
patrons whenever a food service facility:
(a)
Prepares food and provides seating; or
(b) Is a carry-out facility with indoor
tables used for dining;
(5) Installed in accordance with applicable
State and local laws, ordinances, and regulations;
(6) Designed with fixtures that are:
(a) Of sanitary design; and
(b) Readily cleanable;
(7) Kept:
(a) Clean;
(b) In good repair; and
(c) Free of objectionable odor; and
(8) Supplied with:
(a) Toilet tissue at each toilet at all
times; and
(b) Receptacles that are
easily cleanable and covered for waste materials in toilet rooms for
women;
J.
Toilet rooms:
(1) Are completely
enclosed;
(2) Are equipped with
self-closing doors except when a toilet room without doors is approved by the
approving authority based on a review that shows that:
(a) Doors would impede the use of the toilet
room; and
(b) The requirements in
§J(3)-(6) of this regulation are met;
(3) Provide privacy;
(4) Are provided mechanical ventilation that:
(a) Exhausts air at the rate of 2 cubic feet
per minute per square foot of floor area; and
(b) Allows the entrance of an equal amount of
makeup air;
(5) Prevent
the entry of insects and vermin; and
(6) Do not open directly into the kitchen or
food preparation areas;
K. Hand washing facilities are:
(1) Located:
(a) In each food preparation and processing
area;
(b) In each utensil washing
area; and
(c) Adjacent to all
toilet rooms;
(2)
Accessible at all times;
(3)
Equipped with an adequate supply of hand-cleaning soap or detergent;
(4) Equipped with a means of drying hands,
such as:
(a) Individual towels in dispensers;
or
(b) An effective hand-drying
device;
(5) Equipped
with a waste receptacle; and
(6)
Kept clean and in good repair;
L. Hand sinks are:
(1) Installed in accordance with applicable
State and local laws, ordinances, and regulations;
(2) Able to discharge:
(a) Hot and cold running water; or
(b) Tempered running water at a temperature
of at least 100°F through:
(i) A mixing
valve;
(ii) A combination faucet;
or
(iii) Any slow closing or
metering faucet that provides a flow of water for at least 15 seconds before
the faucet has to be reactivated; and
M. Utensil washing vats, food
preparation sinks, or mop sinks are not used as hand sinks.