An annual sanitary survey of each water bottling plant shall be made by the Department to determine its conformance with the U.S. FDA requirements under 21 CFR Part 129, including the following standards:
A. PLANT SURROUNDINGS.
1. Immediate plant surroundings shall be kept
clean, neat, and free from conditions which might attract or harbor flies,
other insects, and rodents, or which otherwise constitute a nuisance or
unsanitary conditions.
2. Surface
drainage shall be diverted away from the source well.
3. Source well shall have a sanitary seal and
the well house shall be secured with a lock.
4. Source overflow pipes and vents shall be
screened with #24 mesh screening.
B. BUILDING AND ROOMS.
1. All rooms shall be of sufficient size to
allow for the proper installation of equipment and to facilitate its
maintenance.
2. All bottling rooms
shall be separated from other plant operations or storage areas by tight walls
and self-closing doors to protect against contamination. No storage should be
permitted in bottling rooms.
3.
Plant buildings shall be insect, bird and rodent proof.
4. Ambient ozone shall be vented to the
outside, and the vent shall have a #24 mesh screen. All persons engaged in
handling ozonator water disinfection components must be provided with proper
Personal Protective Equipment (PPE), and shall use gloves and a chemical
cartridge respirator. All such equipment shall be maintained in a clean and
serviceable condition in accordance with Occupational Safety and Health
Administration (OSHA) and Maine Department of Labor (DOL) standards.
5. Piping system shall be free of excessive
leaks or other sources of contamination.
6. Locker and lunch rooms shall be separate
from plant operations and storage areas, and have self-closing doors, shall be
clean and sanitary, and have refuse containers provided.
C. FLOORS.
1. The floor shall be smooth, impervious,
properly drained, and maintained in a state of good repair, and shall be kept
clean and free from waste, litter, and extraneous material. Floors in new
construction in wet areas shall be pitched one-fourth inch per foot to properly
trapped drains.
2. Floors in the
bottling room shall be cleaned and disinfected daily in accordance with Section
9.F.3. of these Rules.
3.
Wastewater shall be disposed of in accordance with State and Local Plumbing
Codes.
D. WALLS AND CEILINGS.
1. Walls and ceilings of bottling
areas shall have a smooth, cleanable surface and shall be kept clean and in
good repair.
E. DOORS AND WINDOWS.
1. All outside openings into the
bottling facility and bottling areas shall be effectively screened with #24
mesh screening and/or otherwise protected against the entry of insects, dust,
and airborne contamination.
F. EQUIPMENT FOR COLLECTION, STORAGE AND PROCESSING OF WATER.
1. EQUIPMENT. All
equipment shall be of a sanitary design and shall be constructed of non-toxic,
non-absorbent material which will withstand sanitization and which will not
impart flavors, color or odor to the bottled water.
2. STORAGE TANKS. Storage tanks shall be
tightly closed to exclude all foreign matter. Storage tanks shall be thoroughly
cleaned a minimum of once per year, in accordance with the manufacturer's
specifications and in compliance with Section 9.F.3. of these Rules.
3. CLEANING/SANITIZING PROCEDURE. All product
storage tanks, piping, filling equipment, container washers, cappers and other
equipment used to store, handle, transport, and package the water shall be
inspected, maintained, cleaned, and sanitized according to the following
requirements:
(a) Wash surfaces with 100 ppm
chlorine water solution at 75[DEGREE] F or higher for not less than 1 minute
followed by flushing with operations water or product water (to obtain 100 ppm,
add 1.0 oz. of approved chlorine bleach (5.25% chlorine) to 4 gallons of
water).
(b) Spray wet surface with
100 ppm chlorine solution at 75[DEGREE] F for not less than 1 minute followed
by flushing with operations water or product water. This is to be used on
surfaces that are not reached by the above treatment.
(c) Satisfactory results may also be obtained
by use of other bactericides such as quaternary ammonium compounds, organic
chlorine compounds, and bactericidal agents containing iodine or bromine. As
the effectiveness of these agents may be expected to vary with temperature, pH,
and with other components of specific formulations, they should not be used
unless the Department has approved their usage under specified
condition.
(d) An alternative
cleaning and sanitizing procedure may be employed in accordance with the
chemical manufacturer's recommendations and with prior approval from the
Department.
(e) Wastewater shall be
disposed of in accordance with State and Local Plumbing Codes.
4. SANITIZING FILTERS. Softeners,
charcoal filters, de-mineralizers, etc., shall be sanitized on the basis of
recommendations by the manufacturer. Such manuals shall be available for
inspection by the Department.
5.
MULTIFOODS EQUIPMENT. In order to minimize the potential for microbiological
contamination of the finished product, noncarbonated bottled water shall not be
transported, stored, processed, or bottled in or through lines or equipment
through which milk, fruit juice, or other food products have passed and is
likely to contribute nutrients for microbial growth, unless said lines,
equipment, or holding tanks have been cleaned in accordance with Section 9.F.3.
of these Rules.
(a) Bottled water may be
processed through lines or equipment used also for other food products under
the following conditions:
1. Before being used
for the bottling of water - filling equipment, process lines, including storage
tanks and associated equipment which is designed to be cleaned in-place and
which is used for filling other food products shall be thoroughly cleansed and
sanitized in-place in accordance with the manufacturer's specifications and in
compliance with Section 9.F.3. of these Rules.
2. Immediately following completion of
filling operations for any food product other than water, the filler shall be
thoroughly rinsed internally and externally with potable water.
3. Any alternate cleaning, rinsing, or
sanitizing operations or processes not described in this Section shall be
consistent with FDA requirements and receive prior Department
approval.
6. DEDICATED EQUIPMENT.
Bottled water shall not be transported or stored in bulk tanks, or processed or
bottled through equipment or lines used for any non-food product.
G. CLEANING AND SANITIZING CONTAINERS.
1. MULTI-USE
CONTAINERS. All multi-use containers shallbe thoroughly cleaned by washing with
an effective, approved cleansing solution, having a temperature of not less
than 120[DEGREE] F, followed by application of a bactericidal solution as
described in the following sections.
(a)
Method A: Clean by exposing all surfaces with not less than 21/12 % approved
caustic solution at a minimum temperature of 120[DEGREE] F for not less than 1
minute where high velocity jets are used and for not less than 3 minutes where
soaker type container washers are used, followed by a thorough rinsing with
operations water or product water.
(b) Method B: Sanitize with 100 ppm chlorine
water solution at 75[DEGREE] F for not less than 30 seconds, followed by a
thorough rinsing with operations water or product water.
(c) Method C: Sanitize with 200 ppm approved
quaternary ammonium water solution at 75[DEGREE] F for not less than 2 minutes,
followed by a thorough rinsing with operations water or product
water.
(d) An alternative cleaning
and sanitizing procedure may be employed in accordance with the tank
manufacturer recommendations and with prior approval from the
Department.
2. QUALITY
ASSURANCE/QUALITY CONTROL. Containers shall be protected from contamination
between washers and filters. Used containers shall not be stored in the area
provided for the storage of sanitized containers. Containers shall be inspected
by visual and olfactory means (at a minimum) to prevent the use of contaminated
bottles.
H. FILLING AND CLOSING CONTAINERS:
1. CONTAMINATION
PREVENTION. Filling and closing operations shall be conducted to prevent
contamination of water being bottled.
2. FILTER RESERVOIR. The filter reservoir
shall be kept covered at all times and the inlet designed to prevent entrance
of condensation.
3. FILLER. Filling
valves shall be equipped with a condensation-diverting apron to prevent any
outside condensate from dripping into the container being filled.
I. CROSS CONNECTIONS:
1. CROSS CONNECTIONS ARE PROHIBITED. No
cross-connections shall exist between the product water supply lines and any
other sources of water. Where operations water from a municipal or other
regulated source is supplied to washers and may be used for flushing, the use
of separate lines, valves, and pumps shall be employed for each water
source.
J. PERSONNEL-CLEANLINESS:
1. HAND WASHING. Hands
shall be thoroughly washed before commencing plant functions, and as often as
may be required to remove soil and contamination, and upon returning from the
toilet room.
2. CLOTHING. All
personnel shall wear clean outer garments, and wear hairnets, headbands, caps
or other hair restraints.
3.
JEWELRY. Employees shall remove all insecure jewelry to prevent contamination
of product or equipment, excluding wedding bands.
4. SICK EMPLOYEES. No person infected with
any disease in a communicable form, or while a carrier of such disease, and no
person with an infected cut or lesion shall work in any processing area in any
capacity where there is a likelihood of such person contaminating
product-contact surfaces with pathogenic organisms.
5. CONTAMINATION PREVENTION. Employees shall
take necessary precautions to protect against contamination of product,
product-contact surfaces, or product-packaging materials with microorganisms or
foreign substances including, but not limited to: perspiration, hair,
cosmetics, tobacco, chemicals, and medicines applied to the skin.
6. EDUCATION AND TRAINING. Product handlers
and supervisors shall receive appropriate training in proper principles,
techniques and practices of plant and production sanitation and shall be
informed of the public health dangers of poor personal hygiene and unsanitary
practices.
7. SUPERVISION.
Responsibility for assuring compliance by all personnel with all requirements
of Section 9 of these Rules shall be clearly assigned to competent supervisory
personnel.
K. TOILET FACILITIES:
1. TOILETS. Toilets shall be
adequate for the number of employees, and toilet rooms shall have self-closing
doors not opening directly into any rooms used for manufacturing, processing or
packaging. Toilets and all hand washing facilities shall be maintained in a
clean and sanitary condition. The toilet room shall be ventilated to the
outside, kept free of odors, and be in good repair. Washable receptacles shall
be provided for disposal of hand drying articles or waste material. A covered
waste receptacle must be provided in toilet rooms that are used by
women.
2. WASTEWATER DISPOSAL. All
plumbing shall comply with the State and Local plumbing codes.
L. HANDWASHING FACILITIES.
1. Hot and cold, running water, soap, and
individual sanitary towels shall be provided.
2. Hand washing facilities shall be kept
clean and shall be conveniently located to the bottling area and toilet
facilities.
3. Employee hand wash
remindersigns shall be posted at each hand washing facility.
M. STORAGE OF SINGLE SERVICE CONTAINERS.
1. Appropriate clean, dry storage
facilities shall be provided for single service containers, closure materials,
paper for wrapping, adhesives and other production materials to provide
protection from splash, insects, dust, and other contamination.
2. The materials shall be stored on pallets 6
inches above the floor and 18 inches away from any wall to facilitate cleaning
and further provide protection from contamination.
3. Partially used cartons of single service
glass, plastic bottles, caps or other closures material shall be resealed
between uses.
N. ANIMALS.
1. No animals or fowl shall be kept
or allowed in any bottling works or other place where bottled waters are
produced. Effective measures shall be taken to prohibit contamination, in or on
the premises by animals or insects.
O. TEST KITS.
1. SANITIZING SOLUTIONS. Test kits shall be
kept at the bottling plant for purposes of checking the strength of the various
sanitizing solutions.
2.
DISINFECTION. Test kit(s) shall be kept available at the bottling plant for
purposes of checking ozone or chlorine-finished product residuals.
Disclaimer: These regulations may not be the most recent version. Maine may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.