Section 144-232-8-800.0 - ELECTRICAL REQUIREMENTS
Universal Citation: 10 ME Code Rules ยง 144-232-8-800.0
Current through 2024-38, September 18, 2024
800.1. Electric code: Pump installers shall comply with National Electrical Code requirements.
800.2 Securing the wire: Number 10, 12, or 14 gauge electrical wire shall be secured to the drop pipe in a well at a minimum of 10 foot intervals and less than number 10 gauge electrical wire shall be secured to the drop pipe at a minimum of 5 foot intervals.
800.3 Securing materials: Materials used for securing the wire to the pipe shall not contain materials hazardous to the water quality.
Disclaimer: These regulations may not be the most recent version. Maine may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.