Section 144-232-5-502.0 - Guidelines for Standing Column Wells
Current through 2024-38, September 18, 2024
502.1 Total depth: The total depth of a standing column well is determined by adding the following items:
502.2 Recirculation distance: The minimum recommended recirculation distance per ton of heat pump capacity for a single family residential detached home is as follows:
502.3 Pump tests: It is recommended that a pump test, sufficient to evaluate the actual drawdown in the well, be completed for standing column wells to be used for domestic water and/or bleed water. The pumping rate to be used for the pump test should be no less than the total of the domestic water use and any anticipated geothermal bleed. The pump test should proceed until water levels are stabilized in the well. For standing-column wells, it is recommended that a driller's log be recorded and include the following:
502.4 Pump depth: The depth of the pump setting and the depth of the discharge of the return pipe in the well shall be determined from the results of the pump test and shall be set so the discharge of the return pipe and the pump intake shall always be submerged below the lowest pumping water level.
502.5 Sediment filters: A sediment or spin-down filter should be installed on the intake line before the heat pump to prevent sediment from the well damaging the heat pump heat exchanger.
502.6 Additional design requirements: Before drilling any standing column well to be utilized as a heat source for any structure other than a single-family, residential, detached home and associated structures (for example, garages and other outbuildings), the driller shall first obtain a design for that specific well provided by either a Professional Engineer (PE) or a Certified Geothermal Designer (CGD)
502.7 Maine DEP requirements: A driller who drills either a standing column well with bleed, or an open-to-recycle well, and a pump installer who installs a pump system into such a well, shall perform the work in accordance with current Maine Department of Environmental Protection rules regulating the proper discharge of water from the well to a location other than back into the same well.