Code of Maine Rules
10 - DEPARTMENT OF HEALTH AND HUMAN SERVICES
144 - DEPARTMENT OF HEALTH AND HUMAN SERVICES - GENERAL
Chapter 220 - Rules Relating to Radiation Protection
Part D - STANDARDS FOR PROTECTION AGAINST RADIATION
Subpart C - OCCUPATIONAL DOSE LIMITS
Section 144-220-D-C-1202 - Compliance with requirements for summation of external and internal doses
Current through 2024-38, September 18, 2024
A. If the licensee or registrant is required to monitor pursuant to both D.1502.A and B, the licensee or registrant shall demonstrate compliance with the dose limits by summing external and internal doses. If the licensee or registrant is required to monitor only pursuant to D.1502.A or only pursuant to D.1502.B, then summation is not required to demonstrate compliance with the dose limits. The licensee or registrant may demonstrate compliance with the requirements for summation of external and internal doses by meeting one of the conditions specified in paragraph B of this Section and the conditions in paragraphs C and D of this Section. Note: The dose equivalents for the lens of the eye, the skin, and the extremities are not included in the summation, but are subject to separate limits.
B. Intake by inhalation. If the only intake of radionuclides is by inhalation, the total effective dose equivalent (TEDE) limit is not exceeded if the sum of the deep-dose equivalent divided by the total effective dose equivalent limit, and one of the following, does not exceed unity:
C. Intake by oral ingestion. If the occupationally exposed individual also receives an intake of radionuclides by oral ingestion greater than 10 percent of the applicable oral ALI, the licensee or registrant shall account for this intake and include it in demonstrating compliance with the limits.
D. Intake through wounds or absorption through skin. The licensee or registrant shall evaluate and, to the extent practical, account for intakes through wounds or skin absorption. Note the intake through intact skin has been included in the calculation of DAC for hydrogen-3 and does not need to be further evaluated.