Code of Maine Rules
06 - DEPARTMENT OF ENVIRONMENTAL PROTECTION
096 - DEPARTMENT OF ENVIRONMENTAL PROTECTION - GENERAL
Chapter 124 - TOTAL REDUCED SULFUR CONTROL FROM KRAFT PULP MILLS
Section 096-124-6 - Test Methods
Current through 2024-38, September 18, 2024
A.For the purpose of determining compliance with Section 3 of this Chapter, the following EPA Reference Methods from Appendix A of 40 CFR Part 60 and Chapter 117 shall be used:
E=(CTRS) (F) (Qsd)/BLS
Where: E=mass of TRS emitted per unit of black liquor solids (g/kg) or (lb./ton).
CTRS= average combined concentrations of TRS (ppm), as determined by Method 16, 16A or 16B during the test period.
F=0.001417 g H2S/m3 ppm for metric units.
=0.08844 x 10-6 lb. H2S/ft3ppm for English units.
Qsd= dry volumetric stack gas flow rate (dscm/hr or dscf/hr), corrected to standard conditions.
BLS= black liquor solids feed rate (kg/hr or ton/hr).
B. All concentrations of TRS required to be measured by this section from lime kilns, incinerators, or other combustion devices shall be corrected to ten (10)% oxygen by volume and those concentrations from recovery furnaces shall be corrected to eight (8)% oxygen by volume. These corrections shall be made in the manner specified in Section 5(A)(3) of this Chapter.
C. The Department and EPA may approve equivalent test methods.