6-201 Cleanability
6-201.11 Floors, Walls, and Ceilings.
Except as specified under §6 -201.14, the floors, floor coverings, walls, wall coverings, and ceilings shall be designed, constructed, and installed so they are SMOOTH and EASILY CLEANABLE, except that antislip floor coverings or applications may be used for safety reasons.
6-201.12 Floors, Walls, and Ceilings, Utility Lines.
(A) Utility service lines and pipes may not be unnecessarily exposed.
(B) Exposed utility service lines and pipes shall be installed so they do not obstruct or prevent cleaning of the floors, walls, or ceilings.
(C) Exposed horizontal utility service lines and pipes may not be installed on the floor.
6-201.13 Floor and Wall Junctures, Coved, and Enclosed or Sealed.
(A) In FOOD ESTABLISHMENTS in which cleaning methods other than water flushing are used for cleaning floors, the floor and wall junctures shall be coved and closed to no larger than 1 mm (one thirty-second inch).
(B) The floors in FOOD ESTABLISHMENTS in which water flush cleaning methods are used shall be provided with drains and be graded to drain, and the floor and wall junctures shall be coved and SEALED.
6-201.14 Floor Carpeting, Restrictions and Installation.
(A) A floor covering such as carpeting or similar material may not be installed as a floor covering in FOOD preparation areas, walk-in refrigerators, WAREWASHING areas, toilet room areas where handwashing lavatories, toilets, and urinals are located, REFUSE storage rooms, or other areas where the floor is subject to moisture, flushing, or spray cleaning methods.
(B) If carpeting is installed as a floor covering in areas other than those specified under ¶ (A) of this section, it shall be:
6-201.15 Floor Covering, Mats and Duckboards.
Mats and duckboards shall be designed to be removable and EASILY CLEANABLE.
6-201.16 Wall and Ceiling Coverings and Coatings.
(A) Wall and ceiling covering materials shall be attached so that they are EASILY CLEANABLE.
(B) Except in areas used only for dry storage, concrete, porous blocks, or bricks used for indoor wall construction shall be finished and SEALED to provide a SMOOTH, nonabsorbent, EASILY CLEANABLE surface.
6-201.17 Walls and Ceilings, Attachments.
(A) Except as specified in ¶ (B) of this section, attachments to walls and ceilings such as light fixtures, mechanical room ventilation system components, vent covers, wall mounted fans, decorative items, and other attachments shall be EASILY CLEANABLE.
(B) In a CONSUMER area, wall and ceiling surfaces and decorative items and attachments that are provided for ambiance need not meet this requirement if they are kept clean.
6-201.18 Walls and Ceilings, Studs, Joists, and Rafters.
Studs, joists, and rafters may not be exposed in areas subject to moisture. This requirement does not apply to TEMPORARY FOOD ESTABLISHMENTS.
6-202 Functionality
6-202.11 Light Bulbs, Protective Shielding.
(A) Except as specified in ¶ (B) of this section, light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed FOOD; clean EQUIPMENT, UTENSILS, and LINENS; or unwrapped SINGLE-SERVICE and SINGLE-USE ARTICLES.
(B) Shielded, coated, or otherwise shatter-resistant bulbs need not be used in areas used only for storing FOOD in unopened packages, if:
(C) An infrared or other heat lamp shall be protected against breakage by a shield surrounding and extending beyond the bulb so that only the face of the bulb is exposed.
6-202.12 Heating, Ventilating, Air Conditioning System Vents.
Heating, ventilating, and air conditioning systems shall be designed and installed so that make-up air intake and exhaust vents do not cause contamination of FOOD, FOOD-CONTACT SURFACES, EQUIPMENT, or UTENSILS.
6-202.13 Insect Control Devices, Design and Installation.
(A) Insect control devices that are used to electrocute or stun flying insects shall be designed to retain the insect within the device.
(B) Insect control devices shall be installed so that:
6-202.14 Toilet Rooms, Enclosed.
A toilet room located on the PREMISES shall be completely enclosed and provided with a tight-fitting and self-closing door except that this requirement does not apply to a toilet room that is located outside a FOOD ESTABLISHMENT and does not open directly into the FOOD ESTABLISHMENT such as a toilet room that is provided by the management of a shopping mall.
6-202.15 Outer Openings, Protected.
(A) Except as specified in ¶¶ (B), (C), and (E) and under ¶ (D) of this section, outer openings of a FOOD ESTABLISHMENT shall be protected against the entry of insects and rodents by:
(B) Paragraph (A) of this section does not apply if a FOOD ESTABLISHMENT opens into a larger structure, such as a mall, airport, or office building, or into an attached structure, such as a porch, and the outer openings from the larger or attached structure are protected against the entry of insects and rodents.
(C) Exterior doors used as exits need not be self-closing if they are:
(D) Except as specified in ¶¶ (B) and (E) of this section, if the windows or doors of a FOOD ESTABLISHMENT, or of a larger structure within which a FOOD ESTABLISHMENT is located, are kept open for ventilation or other purposes or a TEMPORARY FOOD ESTABLISHMENT is not provided with windows and doors as specified under ¶ (A) of this section, the openings shall be protected against the entry of insects and rodents by:
(E) Paragraph (D) of this section does not apply if flying insects and other pests are absent due to the location of the ESTABLISHMENT, the weather, or other limiting condition.
6-202.16 Exterior Walls and Roofs, Protective Barrier.
Perimeter walls and roofs of a FOOD ESTABLISHMENT shall effectively protect the establishment from the weather and the entry of insects, rodents, and other animals.
6-202.17 Outdoor Food Vending Areas, Overhead Protection.
If located outside, a machine used to vend FOOD shall be provided with overhead protection except that machines vending canned BEVERAGES need not meet this requirement.
6-202.18 Outdoor Servicing Areas, Overhead Protection.
SERVICING AREAS shall be provided with overhead protection except that areas used only for the loading of water or the discharge of SEWAGE and other liquid waste, through the use of a closed system of hoses, need not be provided with overhead protection.
6-202.19 Outdoor Walking and Driving Surfaces, Graded to Drain.
Exterior walking and driving surfaces shall be graded to drain.
6-202.110 Outdoor Refuse Areas, Curbed and Graded to Drain.
Outdoor REFUSE areas shall be constructed in accordance with LAW and shall be curbed and graded to drain to collect and dispose of liquid waste that results from the REFUSE and from cleaning the area and waste receptacles.
6-202.111 Private Homes and Living or Sleeping Quarters, Use Prohibition.
A private home, a room used as living or sleeping quarters, or an area directly opening into a room used as living or sleeping quarters may not be used for conducting FOOD ESTABLISHMENT operations, unless approved by the Regulatory Authority.
6-202.112 Living or Sleeping Quarters, Separation.
Living or sleeping quarters located on the PREMISES of a FOOD ESTABLISHMENT such as those provided for lodging registration clerks or resident managers shall be separated from rooms and areas used for FOOD ESTABLISHMENT operations by complete partitioning and solid self-closing doors.