A. General
1. This rule governs all fumigation of
residential and commercial structures, ships, railcars, trucks, commodity
containers and vaults within the state of Louisiana, including ships at anchor
in rivers within the borders of Louisiana and ships at anchor within a 3-mile
limit off the coast of Louisiana.
2. The licensee shall comply with the
Structural Pest Control Commission rules and regulations and shall follow all
other applicable state and federal rules and regulations.
3. The licensee is responsible for compliance
with all label and labeling requirements.
4. The licensee is responsible for giving any
notice to law enforcement and/or fire protection agencies required by any
governing body of the locality in which the fumigation will take
place.
5. The licensee shall make
certain that personal protection equipment for the fumigant being used is
immediately accessible where the fumigation is being done.
6. The licensee shall remove all signs,
fumigation containers and/or materials, and any other debris which accumulated
as a direct result from the fumigation.
7. The licensee shall have all gas
detection/monitoring instruments for the fumigant being used properly
calibrated to meet manufacturer standards prior to the application of the
fumigant.
B. Requirements for Structural Fumigation
1. The permittee or
primary licensee shall give notice, in writing, to be received by the
department at least 24 hours prior to structural fumigation. Notice to the
department shall include the following items:
a. time and place where the fumigation will
take place;
b. name, address and
emergency phone number of the licensee;
c. name of the fumigant to be used;
d. a brief description of the property to be
fumigated;
e. target
pest;
f. location of target pest;
and
g. other information the
commission requests.
2.
When notice cannot be given as required by
§147. B 1, notice shall
be given by phone but shall be confirmed in writing, to be received by the
commission within 24 hours after the telephone notice.
3. A licensed fumigator shall personally
inspect all structures that are to be fumigated while they are being tented or
sealed after the structure has been evacuated.
4. A licensed fumigator shall seal or
supervise the sealing or the area to be fumigated and assure that there is
proper and secure sealing to confine the fumigant to the area that is to be
fumigated, prior to the release of the fumigant.
5. A licensed fumigator shall see that a sign
or signs of sufficient size as to be conspicuous and bearing the word "poison"
and the skull-and-crossbones symbol, is prominently displayed at all entrances
to the area being fumigated continuously from the time the area is sealed until
ventilation is completed.
6. When
tarp fumigation is being used, in addition to the signs on each entrance of the
building, there shall be at least one sign on each side of the exterior tarp.
If any side of the building exceeds 35 feet, additional signs will be added.
The maximum distance between signs of any side of a building will be 60
feet.
7. Two test lines with at
least 1/4 inch outside diameter shall be appropriately located on the first
floor of the structure(s) being fumigated to permit sufficient readings of the
fumigant concentrate to determine its efficacy in destroying insects. They
shall be on opposite sides of the building. In multi-story buildings the lines
shall be on different floors. A written record of fumigant level readings shall
be maintained during progress of job and will become part of job
file.
8. A licensed fumigator shall
post a guard(s) to prevent entry by an unauthorized person into the area being
fumigated. The guard is not required to be a licensed pest control operator or
registered employee.
9. Whenever
one unit of a complex containing more than one unit is to be fumigated, all
units of the building to be fumigated shall be evacuated during fumigation and
until such time as the fumigated area is declared safe for occupancy. A
licensed fumigator shall inspect all units of a complex.
10. A licensed fumigator shall be present
when the fumigant is released and immediately prior to the time when the
fumigated area is declared safe for occupancy. At least one other person,
trained in fumigation in addition to the above, shall be present when the
fumigant is released and immediately prior to the time when the fumigation area
is declared safe for occupancy.
11.
A licensed fumigator shall personally inspect the area which was fumigated when
ventilation is completed to assure that the fumigated area, and adjacent areas
as appropriate, is safe for occupancy.
C. Requirements for Shipboard Fumigation
1. A licensed fumigator shall be present for
the initial application of fumigant.
2. A licensed fumigator is responsible to
declare the ship safe for occupancy.
D. Requirements for Commodity Fumigation. A licensed fumigator shall:
1. check inside the
container along the junctures to be sealed before fumigation;
2. all openings in vehicles being fumigated
must be sealed;
3. inside and
outside warning signs shall be posted as required by labeling and label
requirements;
4. after releasing
the fumigant, check for leakage and repair any leaks which occur;
5. the permittee or licensed fumigator
licensee shall notify the consignee, in writing, of the fumigant being used,
antidotes and the proper procedures for handling any vehicle(s) or commodity
container(s) which is shipped under gas.
AUTHORITY NOTE: Promulgated in accordance with R.S. 3:3306.
Disclaimer: These regulations may not be the most recent version. Louisiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.