Louisiana Administrative Code
Title 51 - PUBLIC HEALTH-SANITARY CODE
Part XIV - Plumbing
Chapter 5 - Water Heaters
Section XIV-505 - Minimum Capacities for Residential Water Heaters
Current through Register Vol. 50, No. 9, September 20, 2024
A. Water heaters installed in residential occupancies may be sized in accordance with the following Table 505.
Table 505 Minimum Capacities For Water Heaters1,2 |
|||
Number of Bathrooms |
1 to 1.5 |
2 to 2.5 |
3 to 3.5 |
Number of Bedrooms |
1 2 3 |
2 3 4 5 |
3 4 5 6 |
First Hr Rating Gal. |
42 54 54 |
54 67 67 80 |
67 80 80 80 |
Nom. Tank Size, Gal. Gas Water Heaters |
20 30 30 |
30 40 40 50 |
40 50 50 50 |
Elect. Water Heaters |
30 50 50 |
50 66 66 80 |
66 80 80 80 |
Oil Water Heaters |
30 30 30 |
30 30 30 30 |
30 30 30 30 |
NOTES:
B. Non-storage and solar water heaters shall be sized with sufficient capacity to meet the appropriate first hour rating shown in Table 505 above.
AUTHORITY NOTE: Promulgated in accordance with R.S. 40:4(A)(7) and R.S. 40:5(2)(3)(7)(9)(16)(17)(20).