Louisiana Administrative Code
Title 51 - PUBLIC HEALTH-SANITARY CODE
Part VI - Manufacturing, Processing, Packing and Holding of Food, Drugs and Cosmetics
Chapter 3 - Current Good Manufacturing Practices in Manufacturing, Processing, Packing or Holding Human Food
Section VI-313 - Plant Construction and Design [formerly paragraph 6:057]
Universal Citation: LA Admin Code VI-313
Current through Register Vol. 50, No. 9, September 20, 2024
A. Plant buildings and structures shall be suitable in size, construction, and design to facilitate maintenance and sanitary operations for food-processing purposes. The plant and facilities shall comply with the following paragraphs.
1. [formerly paragraph 6:058] Provide
sufficient space for such placement of equipment and storage of materials as is
necessary for sanitary operations and production of safe food. Floors, walls,
and ceilings in the plant shall be of such construction as to be readily
cleanable and shall be kept clean and in good repair. Fixtures, ducts, and
pipes that drip or produce condensate may contaminate foods, raw materials or
food-contact surfaces, and shall not be suspended over working areas. Aisles or
working spaces between equipment and walls shall be unobstructed and of
sufficient width to permit employees to perform their duties without
contamination of food or food contact surfaces with clothing or personal
contact.
2. [formerly paragraph
6:059] Provide separation by partition, location, or other effective means for
those operations which may cause contamination of food products with
undesirable microorganisms, chemicals, filth or other extraneous
material.
3. [formerly paragraph
6:060] Provide at least 40 foot-candles of lighting to hand washing areas,
dressing and locker rooms, and toilet rooms and to all areas where food or food
ingredients are examined, processed, or stored and where equipment and utensils
are cleaned. Light bulbs, fixtures, skylights, or other glass suspended over
exposed food in any step of preparation shall be of the safety type or
otherwise protected to prevent food contamination in case of
breakage.
4. [formerly paragraph
6:061] Provide adequate ventilation or control equipment to minimize odors and
noxious fumes or vapors (including steam) in areas where they may contaminate
food. Such ventilation or control equipment shall not create conditions that
may contribute to food contamination by airborne contaminants.
5. [formerly paragraph 6:062] Provide, where
necessary, effective screening or other protection against birds, animals, and
vermin (including, but not limited to, insects and rodents).
AUTHORITY NOTE: Promulgated in accordance with the provisions of R.S. 40:4(A)(1)(a). Also see R.S. 40:601 et seq.
Disclaimer: These regulations may not be the most recent version. Louisiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.