A. Level 1 ARCP Bedroom Requirements
1. A level 1
ARCP shall ensure that each single occupancy bedroom space has a floor area of
at least 100 net square feet and that each multiple occupancy bedroom space has
a floor area of at least 70 net square feet for each resident. Bathrooms and
closets/wardrobes shall not be included in the calculation of square
footage.
2. There shall be no more
than two residents per bedroom. All shared living arrangements shall be agreed
to in writing by both parties.
3. A
room where access is through a bathroom or another bedroom shall not be
approved or used as a residents bedroom.
4. Privacy of residents shall be maintained
in residents personal space.
B. Level 2 ARCP Bedroom Requirements
1. A level 2 ARCP shall ensure that each
single occupancy bedroom space has a floor area of at least 100 net square feet
and that each multiple occupancy bedroom space has a floor area of at least 70
net square feet for each resident. Bathrooms and closets/wardrobes shall not be
included in the calculation of square footage.
2. There shall be no more than two residents
per bedroom. All shared living arrangements shall be agreed to in writing by
both parties.
3. A room where
access is through a bathroom or another bedroom shall not be approved or used
as a residents bedroom.
4. Privacy
of residents shall be maintained in residents personal space.
C. Requirements for Resident Bathrooms in Level 1 and 2 ARCPs
1. There
shall be at least one bathroom for every four residents.
2. Bathrooms shall be equipped with one
toilet, bathtub or shower, and a washbasin.
3. Grab bars and non-skid surfacing or strips
shall be installed in all showers and bath areas.
4. Bathrooms shall have floors and walls of
impermeable, cleanable, and easily sanitized materials.
5. Resident bathrooms shall not be utilized
for storage or purposes other than those indicated by this
Subsection.
6. Hot and cold-water
faucets shall be easily identifiable and be equipped with scald control.
a. Hot water temperatures shall not exceed
120 degrees Fahrenheit.
7. Each bathroom shall be supplied with
toilet paper, soap and towels.
8.
Mirrors shall be provided and secured to the wall at convenient heights to
allow residents to meet basic personal hygiene and grooming needs.
9. Bathrooms shall be located so that they
open into the hallway, common area, or directly into the bedroom. If the
bathroom opens directly into a bedroom, it shall be for the use of the
occupants of that bedroom only.
D. Requirements for Resident Apartments in levels 3 and 4
1. All apartments in levels 3
and 4 shall be independent and shall contain at a minimum the following areas:
a. a bedroom/sleeping area that can be
distinguished by sight from other areas in the apartment;
b. a bathroom;
c. a kitchenette that can be distinguished by
sight from other areas in the apartment;
NOTE: Kitchenettes are not required in apartments designated for the specialized dementia care program.
d. a dining/living area; and
e. a closet/wardrobe.
2. Square Footage in Level 3 and 4 ARCPs
a. Efficiency/studio apartments shall have a
minimum of 200 net square feet of floor space, excluding bathrooms and closets
and/or wardrobes.
b. Resident
apartments with separate bedrooms shall be at minimum 190 square feet in living
area excluding bathrooms and 100 square feet for each bedroom excluding closets
and/or wardrobes.
3.
Privacy of residents shall be maintained in all apartments.
4. Each apartment shall have an individual
lockable entrance and exit. All apartments shall be accessible by means of a
master key or similar system that is available at all times in the ARCP and for
use by designated staff.
5. No
apartment shall be occupied by more than two residents regardless of square
footage. All shared living arrangements shall be agreed to in writing by both
residents.
a. It is recognized that there may
be more individuals in an ARCP due to the resident and a spouse or partner
sharing a living unit than is listed as the total licensed capacity.
6. Each apartment shall contain an
outside window. Skylights are not acceptable to meet this
requirement.
7. In new ARCPs
licensed after the effective date of these regulations, the ARCP shall provide
HVAC thermostats that can be individually controlled by the resident, with a
locking mechanism provided, if required, to prevent harm to a
resident.
8. Each apartment shall
have a call system, either wired or wireless, monitored 24 hours a day by the
ARCP staff.
9. Each apartment shall
be equipped for telephone and television cable or central television antenna
system.
10. Each apartment shall
have access to common areas and dining room(s).
11. Kitchenettes
a. For each apartment, the ARCP shall
provide, at a minimum, a small refrigerator, a wall cabinet for food storage, a
small bar-type sink, and a counter with workspace and electrical outlets, a
small cooking appliance, for example, a microwave or a two-burner cook
top.
b. If the residents assessment
indicates that having a cooking appliance in the apartment endangers the
resident, no cooking appliance shall be provided or allowed in the apartment or
the cooking appliance may be disconnected.
12. Bathrooms. Each apartment shall have a
separate and complete bathroom with a toilet, bathtub or shower, and sink. The
bathrooms shall be ADA accessible.
a.
Entrance to a bathroom from one bedroom shall not be through another
bedroom.
b. Grab bars and non-skid
surfacing or strips shall be installed in all showers and bath areas.
c. Bathrooms shall have floors and walls of
impermeable, cleanable, and easily sanitized materials.
d. Resident bathrooms shall not be utilized
for storage or purposes other than those indicated by this
Subsection.
e. Hot and cold-water
faucets shall be easily identifiable and be equipped with scald control.
i. Hot water temperatures shall not exceed
120 degrees Fahrenheit.
f. Each bathroom shall be equipped with an
emergency call system that is monitored 24 hours a day by the ARCP
staff.
13. Storage. The
ARCP shall provide adequate portable or permanent closet(s) in the apartment
for clothing and personal belongings.
AUTHORITY NOTE: Promulgated in accordance with R.S. 36:254 and R.S. 40:2166.1-2166.8.
Disclaimer: These regulations may not be the most recent version. Louisiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.