Louisiana Administrative Code
Title 43 - NATURAL RESOURCES
Part XI - Office of Conservation-Pipeline Division
Subpart 4 - Carbon Dioxide
Chapter 49 - Operating and Maintaining Carbon Dioxide Pipelines
Section XI-4911 - Maximum Operating Pressures (Formerly section 1911)

Universal Citation: LA Admin Code XI-4911

Current through Register Vol. 50, No. 9, September 20, 2024

A. Except for surge pressures and other variations from normal operations, no operator may operate a pipeline at a pressure that exceeds any of the following:

1. the internal design pressure of the pipe determined in accordance with §4309;

2. the design pressure of any other component of the pipeline;

3. 80 percent of the test pressure for any part of the pipeline which has been hydrostatically tested under §4701-4711 of this regulation;

4. 80 percent of the factory test pressure or of the prototype test pressure for any individually installed component which is excepted from testing under §4705

B. No operator may permit the pressure in a pipeline during surges or other variations from normal operations to exceed 110 percent of the operating pressure limit established under Subsection A of this Section. Each operator must provide adequate controls and protective equipment to control the pressure within this limit.

AUTHORITY NOTE: Promulgated in accordance with R.S. 30:4(C)(17) and R.S. 30:1104(A).

Disclaimer: These regulations may not be the most recent version. Louisiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.