Louisiana Administrative Code
Title 43 - NATURAL RESOURCES
Part XI - Office of Conservation-Pipeline Division
Subpart 4 - Carbon Dioxide
Chapter 47 - Hydrostatic Testing of Carbon Dioxide Pipelines
Section XI-4711 - Records (Formerly section 1711)

Universal Citation: LA Admin Code XI-4711

Current through Register Vol. 50, No. 9, September 20, 2024

A. A record must be made of each hydrostatic test and that record must be retained as long as the facility tested is in use.

B. The record required by Subsection A of this Section must include the recording gauge charts, test instrument calibration data, and the reasons for any failure during a test. Where elevation differences in the section under test exceed 100 feet, a profile of the pipeline that shows the elevation and tests sites over the entire length of the test section must be included. Each recording gauge chart must also contain:

1. the operator's name, the name of the person responsible for making the test, and the name of the test company used, if any;

2. the date and time of the test;

3. the minimum test pressure;

4. the test medium;

5. a description of the facility tested; and

6. an explanation of any pressure discontinuities that appear on any chart.

AUTHORITY NOTE: Promulgated in accordance with R.S. 30:4(C)(17) and R.S. 30:1104(A).

Disclaimer: These regulations may not be the most recent version. Louisiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.