Louisiana Administrative Code
Title 43 - NATURAL RESOURCES
Part XI - Office of Conservation-Pipeline Division
Subpart 4 - Carbon Dioxide
Chapter 45 - Construction Requirements for Carbon Dioxide Pipelines
Section XI-4523 - Welding: Arc Burns (Formerly section 1523)
Universal Citation: LA Admin Code XI-4523
Current through Register Vol. 50, No. 9, September 20, 2024
A. Each arc burn must be repaired.
B. An arc burn may be repaired by completely removing the notch by grinding, if the grinding does not reduce the remaining wall thickness to less than the minimum thickness required by the tolerances in the specification to which the pipe is manufactured. If a notch is not repairable by grinding, a cylinder of the pipe containing the entire notch must be removed.
C. A ground may not be welded to the pipe or fitting that is being welded.
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:4(C)(17) and R.S. 30:1104(A).
Disclaimer: These regulations may not be the most recent version. Louisiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.