Louisiana Administrative Code
Title 43 - NATURAL RESOURCES
Part XI - Office of Conservation-Pipeline Division
Subpart 4 - Carbon Dioxide
Chapter 43 - Design Requirements for Carbon Dioxide Pipelines
Section XI-4317 - Used Pipe (Formerly section 1317)

Universal Citation: LA Admin Code XI-4317

Current through Register Vol. 50, No. 9, September 20, 2024

A. Any used pipe installed in a pipeline system must comply with §4315.A.1 and the following:

1. the pipe must be of a known specification and the seam joint factor must be determined in accordance with §4309.E If the specified minimum yield strength or the wall thickness is not known, it is determined in accordance with §4309.B or C as appropriate;

2. there may not be any:
a. buckles;

b. cracks, grooves, gouges, dents, or other surface defects that exceed the maximum depth of such a defect permitted by the specification to which the pipe was manufactured; or

c. corroded areas where the remaining wall thickness is less than the minimum thickness required by the tolerances in the specification to which the pipe was manufactured.

B. However, pipe that does not meet the requirements of Subparagraph A.2.c of this Section may be used if the operating pressure is reduced to be commensurate with the remaining wall thickness.

AUTHORITY NOTE: Promulgated in accordance with R.S. 30:4(C)(17) and R.S. 30:1104(A).

Disclaimer: These regulations may not be the most recent version. Louisiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.