Louisiana Administrative Code
Title 33 - ENVIRONMENTAL QUALITY
Part XV - Radiation Protection
Chapter 17 - Licensing and Radiation Safety Requirements for Irradiators
Section XV-1745 - Inspection and Maintenance
Universal Citation: LA Admin Code XV-1745
Current through Register Vol. 50, No. 9, September 20, 2024
A. The licensee shall perform inspection and maintenance checks that include, as a minimum, each of the following at the frequency specified in the license or license application:
1. operability of each
aspect of the access control system required by LAC 33:XV.1715;
2. functioning of the source position
indicator required by LAC 33:XV.1723.B;
3. operability of the radiation monitor for
radioactive contamination in pool water, required by LAC 33:XV.1743.B, using a
radiation check source, if applicable;
4. operability of the over-pool radiation
monitor at underwater irradiators, as required by LAC 33:XV.1721.B;
5. operability of the product exit monitor
required by LAC 33:XV.1721.A;
6.
operability of the emergency source return control required by LAC
33:XV.1723.C;
7. visual inspection
of leak-tightness of systems through which pool water circulates;
8. operability of the heat and smoke
detectors and extinguisher system required by LAC 33:XV.1719, without turning
extinguishers on;
9. operability of
the means of pool water replenishment required by LAC 33:XV.1725.C;
10. operability of the indicators of high and
low pool water levels required by LAC 33:XV.1725.D;
11. operability of the intrusion alarm
required by LAC 33:XV.1715.I, if applicable;
12. functioning and wear of the system,
mechanisms, and cables used to raise and lower sources;
13. condition of the barrier to prevent
products from hitting the sources or source mechanism, as required by LAC
33:XV.1727;
14. amount of water
added to the pool to determine if the pool is leaking;
15. electrical wiring on required safety
systems for radiation damage; and
16. pool water conductivity measurements and
analysis, as required by LAC 33:XV.1747.B.
B. Malfunctions and defects found during inspection and maintenance checks shall be repaired within time frames specified in the license or license application.
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2001 et seq.
Disclaimer: These regulations may not be the most recent version. Louisiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.