A. Except as provided in §30306 B, C, and D, water must be used as the test medium. [ 49 CFR 195.306(a)]

B. Except for offshore pipelines, liquid petroleum that does not vaporize rapidly may be used as the test medium if: [ 49 CFR 195.306(b)]

1. the entire pipeline section under test is outside of cities and other populated areas; [ 49 CFR 195.306(b)(1) ]

2. each building within 300 feet (91 meters) of the test section is unoccupied while the test pressure is equal to or greater than a pressure which produces a hoop stress of 50 percent of specified minimum yield strength; [ 49 CFR 195.306(b)(2) ]

3. the test section is kept under surveillance by regular patrols during the test; and [ 49 CFR 195.306(b)(3) ]

4. continuous communication is maintained along entire test section. [ 49 CFR 195.306(b)(4) ]

C. Carbon dioxide pipelines must use water as the test medium unless another medium is approved by the Commissioner. [49 CFR 195.306(c)]

D. Air or inert gas may be used as the test medium in low stress pipelines. [ 49 CFR 195.306(d)]

AUTHORITY NOTE: Promulgated in accordance with R.S. 30:753.

Disclaimer: These regulations may not be the most recent version. Louisiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.