A. Each pressure test under §30302 must test all pipe and attached fittings, including components, unless otherwise permitted by §30305. B [ 49 CFR 195.305(a)]

B. A component, other than pipe, that is the only item being replaced or added to the pipeline system need not be hydrostatically tested under §30305. A if the manufacturer certifies that either: [ 49 CFR 195.305(b)]

1. the component was hydrostatically tested at the factory; or [ 49 CFR 195.305(b)(1)]

2. the component was manufactured under a quality control system that ensures each component is at least equal in strength to a prototype that was hydrostatically tested at the factory. [ 49 CFR 195.305(b)(2)]

AUTHORITY NOTE: Promulgated in accordance with R.S. 30:753.

Disclaimer: These regulations may not be the most recent version. Louisiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.