Louisiana Administrative Code
Title 33 - ENVIRONMENTAL QUALITY
Part V - Hazardous Wastes and Hazardous Materials
Subpart 3 - Natural Resources
Chapter 301 - Transportation of Hazardous Liquids by Pipeline [49 CFR Part 195]
Subchapter C - Design Requirements [49 CFR Part 195 Subpart C]
Section V-30171 - Used Pipe [49 CFR 195.114]
Universal Citation: LA Admin Code V-30171
Current through Register Vol. 50, No. 9, September 20, 2024
A. Any used pipe installed in a pipeline system must comply with § 30169. A 1-2 and the following. [ 49 CFR 195.114]
1.
The pipe must be of a known specification and the seam joint factor must be
determined in accordance with § 30161. E. If the specified minimum yield
strength or the wall thickness is not known, it is determined in accordance
with §
30161. B or
§
30161. C as
appropriate. [
49 CFR
195.114(a)]
2. There may not be any: [
49 CFR
195.114(b)]
a. buckles; [
49 CFR
195.114(b)(1)]
b. cracks, grooves, gouges, dents, or other
surface defects that exceed the maximum depth of such a defect permitted by the
specification to which the pipe was manufactured; or [
49 CFR
195.114(b)(2)]
c. corroded areas where the remaining wall
thickness is less than the minimum thickness required by the tolerances in the
specification to which the pipe was manufactured. However, pipe that does not
meet the requirements of
§30171. A.2.c may be
used if the operating pressure is reduced to be commensurate with the remaining
wall thickness. [
49 CFR
195.114(b)(3)]
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:753.
Disclaimer: These regulations may not be the most recent version. Louisiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.