Louisiana Administrative Code
Title 33 - ENVIRONMENTAL QUALITY
Part V - Hazardous Wastes and Hazardous Materials
Subpart 1 - Department of Environmental Quality-Hazardous Waste
Chapter 5 - Permit Application Contents
Subchapter E - Specific Information Requirements
Section V-533 - Specific Part II Information Requirements for Landfills

Universal Citation: LA Admin Code V-533

Current through Register Vol. 50, No. 9, September 20, 2024

Except as otherwise provided in LAC 33:V.1501, owners and operators of facilities that dispose of hazardous waste in landfills must provide the following additional information:

A. a list of the hazardous wastes placed in each landfill or landfill cell;

B. detailed plans and an engineering report describing how the landfill is designed and is or will be constructed, operated and maintained to comply with the requirements of LAC 33:V.1504, 2503, 2504, and 2507. This submission must address the following items:

1. the liner system (except for an existing portion of a landfill), if the landfill must meet the requirements of LAC 33:V.2503.A. If an exemption from the requirement for a liner is sought as provided by LAC 33:V.2503.L, submit detailed plans and engineering and hydrogeological reports, as appropriate, describing alternate designs and operating practices that will, in conjunction with location aspects, prevent the migration of any hazardous constituents into the groundwater or surface water at any future time;

2. the double liner and leak (leachate) detection, collection, and removal system, if the landfill must meet the requirements of LAC 33:V.2503.K. If an exemption from the requirements for double liners and a leak detection, collection, and removal system or alternative design is sought as provided by LAC 33:V.2503.L or M, submit appropriate information;

3. if the leak detection system is located in a saturated zone, submit detailed plans and an engineering report explaining the leak detection system design and operation and the location of the saturated zone in relation to the leak detection system;

4. the construction quality assurance (CQA) plan if required under LAC 33:V.1504;

5. proposed action leakage rate, with rationale, if required under LAC 33:V.2504, and response action plan, if required under LAC 33:V.2508;

6. control of run-on;

7. control of run-off;

8. management of collection and holding facilities associated with run-on and run-off control systems; and

9. control of wind dispersal of particulate matter, where applicable;

C. there are no exemptions from the groundwater protection requirements of LAC 33:V.Chapter 33;

D. a description of how each landfill, including the liner and cover systems, will be inspected in order to meet the requirements of LAC 33:V.2507.B, C, and D. This information should be included in the inspection plan submitted under LAC 33:V.517.G;

E. detailed plans and an engineering report describing the final cover which will be applied to each landfill or landfill cell at closure in accordance with LAC 33:V.2521.A, and a description of how each landfill will be maintained and monitored after closure in accordance with LAC 33:V.2521.B. This information should be included in the closure and post-closure plans;

F. if ignitable or reactive wastes will be landfilled, an explanation of how the standards of LAC 33:V.2511 will be complied with;

G. if incompatible wastes, or incompatible wastes and materials will be landfilled, an explanation of how LAC 33:V.2513 will be complied with;

H. bulk or non-containerized liquid waste or wastes containing free liquids to be landfilled must comply with LAC 33:V.2515;

I. if containers of hazardous waste are to be landfilled, an explanation of how the requirements of LAC 33:V.2517 or LAC 33:V.2519, as applicable, will be complied with;

J. a waste management plan for EPA Hazardous Waste Numbers F020, F021, F022, F023, F026, and F027 describing how a landfill is or will be designed, constructed, operated, and maintained to meet the requirements of LAC 33:V.2523. This submission must address the following items:

1. the volume, physical, and chemical characteristics of the wastes, including their potential to migrate through soil or to volatilize or escape into the atmosphere;

2. the attenuative properties of underlying and surrounding soils or other materials;

3. the mobilizing properties of other materials codisposed with these wastes; and

4. the effectiveness of additional treatment, design, or monitoring techniques.

AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2180 et seq.

Disclaimer: These regulations may not be the most recent version. Louisiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.