Louisiana Administrative Code
Title 33 - ENVIRONMENTAL QUALITY
Part V - Hazardous Wastes and Hazardous Materials
Subpart 1 - Department of Environmental Quality-Hazardous Waste
Chapter 5 - Permit Application Contents
Subchapter E - Specific Information Requirements
Section V-531 - Specific Part II Information Requirements for Land Treatment Facilities

Universal Citation: LA Admin Code V-531

Current through Register Vol. 50, No. 9, September 20, 2024

Except as otherwise provided in LAC 33:V.1501, owners and operators of facilities that use land treatment to dispose of hazardous waste must provide the following additional information:

A. a description of plans to conduct a treatment demonstration as required under LAC 33:V.2707. The description must include the following information:

1. the wastes for which the demonstration will be made and the potential hazardous constituents in the waste;

2. the data sources to be used to make the demonstration (e.g., literature, laboratory data, field data, or operating data);

3. any specific laboratory or field test that will be conducted, including:
a. the type of test (e.g., column leaching, degradation);

b. materials and methods, including analytical procedures;

c. expected time for completion;

d. characteristics of the unit that will be simulated in the demonstration, including treatment zone characteristics, climatic conditions, and operating practices;

B. a description of a land treatment program, as required under LAC 33:V.2705. This information must be submitted with the plans for the treatment demonstration, and updated following the treatment demonstration. The land treatment program must address the following items:

1. the wastes to be land treated;

2. design measures and operating practices necessary to maximize treatment in accordance with LAC 33:V.2703.A including:
a. waste application method and rate;

b. measures to control soil pH;

c. enhancement of microbial or chemical reactions;

d. control of moisture content;

3. provisions for unsaturated zone monitoring, including:
a. sampling equipment, procedures, and frequency;

b. procedures for selecting sampling locations;

c. analytical procedures;

d. chain of custody control;

e. procedures for establishing background values;

f. statistical methods for interpreting results;

g. the justification for any hazardous constituents recommended for selection as principal hazardous constituents, in accordance with the criteria for such selection in LAC 33:V.2711.A;

4. a list of hazardous constituents reasonably expected to be in, or derived from, the wastes to be land treated based on waste analysis performed pursuant to LAC 33:V.1519;

5. the proposed dimensions of the treatment zone;

C. a description of how the unit is or will be designed, constructed, operated, and maintained in order to meet the requirements of LAC 33:V.2303. This submission must address the following items:

1. control of run-on;

2. collection and control of run-off;

3. minimization of run-off of hazardous constituents from the treatment zone;

4. management of collection and holding facilities associated with run-on and run-off control systems;

5. periodic inspection of this unit. (This information should be included in the inspection plan.);

6. control of wind dispersal of particulate matter, if applicable;

D. no food-chain crops are to be grown in or on the treatment zone of the land treatment unit;

E. a description of the vegetative cover to be applied to closed portions of the facility, and a plan for maintaining such cover during the post-closure care period, as required under LAC 33:V.2709.A.8 and C.2. This information should be included in the closure plan and, where applicable, the post-closure plan;

F. if ignitable or reactive wastes will be placed in or on the treatment zone, an explanation of how the requirements of LAC 33:V.2715 will be complied with;

G. if incompatible wastes, or incompatible wastes and materials, will be placed in or on the same treatment zone, an explanation of how LAC 33:V.2717 will be complied with;

H. a waste management plan for EPA Hazardous Waste Numbers F020, F021, F022, F023, F026 and F027 describing how a land treatment facility is or will be designed, constructed, operated, and maintained to meet the requirements of LAC 33:V.2723. This submission must address the following items:

1. the volume, physical, and chemical characteristics of the wastes, including their potential to migrate through soil or to volatilize or escape into the atmosphere;

2. the attenuative properties of underlying and surrounding soils or other materials;

3. the mobilizing properties of other materials codisposed with these wastes; and

4. the effectiveness of additional treatment, design, or monitoring techniques.

AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2180 et seq.

Disclaimer: These regulations may not be the most recent version. Louisiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.