Except as otherwise provided in LAC 33:V.1501, owners and operators of facilities that treat, store, or dispose of hazardous waste in surface impoundments must provide the following additional information:
A. a list of the hazardous wastes placed or to be placed in each surface impoundment;
B. detailed plans and an engineering report describing how the surface impoundment is designed and is or will be constructed, operated and maintained to meet the requirements of LAC 33:V.1504, 2903, 2904, and 2906. This submission must address the following items:
C. a description of how each surface impoundment, including the double liner system, leak detection system, cover system, and appurtenances for control of overtopping, will be inspected in order to meet the requirements of LAC 33:V.2907.B, C, and E. This information must be included in the inspection plan submitted under LAC 33:V.517.G;
D. a description of how each surface impoundment, including the liner and cover systems and appurtenances for control of overtopping, will be inspected in order to meet the requirements of LAC 33:V.2907.B and C;
E. a certification by a qualified engineer which attests to the structure integrity of each dike, as required under LAC 33:V.2907.D. For new units, the owner or operator must submit a statement by a qualified engineer that he will provide such a certification upon completion of construction in accordance with the plans and specifications;
F. a description of the procedure to be used for removing a surface impoundment from service, as required under LAC 33:V.2909.B and C;
G. a description of how hazardous waste residues and contaminated materials will be removed from the unit at closure, as required under LAC 33:V.2911.A. For any wastes not to be removed from the unit upon closure, the owner or operator must submit detailed plans and an engineering report describing how LAC 33:V.2911.B and C will be complied with. This information should be included in the closure plan and, where applicable, the post-closure plan;
H. if ignitable or reactive wastes are to be placed in a surface impoundment an explanation of how LAC 33:V.2913 will be complied with;
I. if incompatible wastes, or incompatible wastes and materials will be placed in a surface impoundment, an explanation of how LAC 33:V.2915 will be complied with;
J. a waste management plan for EPA Hazardous Waste Numbers F020, F021, F022, F023, F026 and F027 describing how the surface impoundment is or will be designed, constructed, operated, and maintained to meet the requirements of LAC 33:V.2917. This submission must address the following items:
K. information on air emission control equipment as required in LAC 33:V.526.
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2180 et seq.