Louisiana Administrative Code
Title 33 - ENVIRONMENTAL QUALITY
Part V - Hazardous Wastes and Hazardous Materials
Subpart 1 - Department of Environmental Quality-Hazardous Waste
Chapter 5 - Permit Application Contents
Subchapter E - Specific Information Requirements
Section V-520 - Specific Part II Information Requirements for Groundwater Protection
Current through Register Vol. 50, No. 9, September 20, 2024
The following additional information regarding protection of groundwater is required from owners or operators of hazardous waste facilities containing a regulated unit except as provided in LAC 33:V.3301.B and C:
A. a summary of the groundwater monitoring data obtained during the interim status period under LAC 33:V.4367, 4369, 4371, 4373, and 4375, where applicable;
B. identification of the uppermost aquifer and aquifers hydraulically interconnected beneath the facility property, including groundwater flow direction and rate, and the basis for such identification (i.e., the information obtained from hydrogeologic investigations of the facility area);
C. on the topographic map required under LAC 33:V.517.B, a delineation of the waste management area, the property boundary, the proposed point of compliance as defined under LAC 33:V.3311, the proposed location of groundwater monitoring wells as required under LAC 33:V.3315, and, to the extent possible, the information required in LAC 33:V.520.B;
D. a description of any known plume of contamination that has entered the groundwater from a regulated unit at the time that the application was submitted that:
E. detailed plans and an engineering report describing the proposed groundwater monitoring program to be implemented to meet the requirements of LAC 33:V.3315;
F. if the presence of hazardous constituents has not been detected in the groundwater at the time of permit application, the owner or operator must submit sufficient information, supporting data, and analyses to establish a detection monitoring program that meets the requirements of LAC 33:V.3317. This submission must address the following items specified under LAC 33:V.3317:
G. if the presence of hazardous constituents has been detected in the groundwater at the point of compliance at the time of the permit application, the owner or operator must submit to the Office of Environmental Services sufficient information, supporting data, and analyses to establish a compliance monitoring program that meets the requirements of LAC 33:V.3319. Except as provided in LAC 33:V.3317.H, the owner or operator must also submit to the Office of Environmental Services an engineering feasibility plan for a corrective action program necessary to meet the requirements of LAC 33:V.3321, unless the owner or operator obtains written authorization in advance from the administrative authority to submit a proposed permit schedule for submittal of such a plan. To demonstrate compliance with LAC 33:V.3319, the owner or operator must address the following items:
H. if hazardous constituents have been measured in the groundwater that exceed the concentration limits established under LAC 33:V.3309, Table 1, or if groundwater monitoring conducted at the time of permit application under LAC 33:V.4367, 4369, 4371, 4373, and 4375 at the waste boundary indicates the presence of hazardous constituents from the facility in groundwater over background concentrations, the owner or operator must submit sufficient information, supporting data, and analyses to establish a corrective action program that meets the requirements of LAC 33:V.3321. However, an owner or operator is not required to submit information to establish a corrective action program if he or she demonstrates to the administrative authority that alternate concentration limits will protect human health and the environment after considering the criteria listed in LAC 33:V.3309.B. An owner or operator who is not required to establish a corrective action program for this reason must instead submit sufficient information to establish a compliance monitoring program that meets the requirements of LAC 33:V.3319 and LAC 33:V.520.F. To demonstrate compliance with LAC 33:V.3321, the owner or operator must address, at a minimum, the items listed in LAC 33:V.520.H.1-4 below (the permit may contain a schedule for submittal of the information required in LAC 33:V.520.H.3 and 4 provided the owner or operator obtains written authorization from the administrative authority prior to submittal of the complete permit application):
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2180 et seq.