A. The owner or operator of each new landfill unit, each lateral expansion of a landfill unit, and each replacement of an existing landfill unit, must install two or more liners and a leachate collection and removal system above and between such liners and operate the leachate collection and removal systems, in accordance with LAC 33:V.2503.L, unless exempted by Subsection C, D, or E of this Section.
B. The owner or operator of each unit referred to in Subsection A of this Section must notify the Office of Environmental Services at least 60 days prior to receiving waste. The owner or operator of each facility submitting notice must file a Part II application within six months of the receipt of such notice.
C. The owner or operator of any replacement landfill unit is exempt from LAC 33:V.4512.A if:
D. The double liner requirement set forth in Subsection A of this Section may be waived by the administrative authority for any monofill, if it meets the requirements specified in Paragraphs D.1 and 2 of this Section.
E. In the case of any unit in which the liner and leachate collection system have been installed pursuant to the requirements of LAC 33:V.4512.A and in good faith compliance with LAC 33:V.4512.A and with guidance documents governing liners and leachate collection systems under LAC 33:V.4512.A, no liner or leachate collection system which is different from that which was so installed pursuant to LAC 33:V.4512.A will be required for such unit by the administrative authority when issuing the first permit to such facility, except that the administrative authority will not be precluded from requiring installation of a new liner when the administrative authority has reason to believe that any liner installed pursuant to the requirements of LAC 33:V.4512.A is leaking.
F. The owner or operator must design, construct, operate, and maintain a run-on control system capable of preventing flow onto the active portion of the landfill during peak discharge from at least a 25-year storm.
G. The owner or operator must design, construct, operate, and maintain a run-off management system to collect and control at least the water volume resulting from a 24-hour, 25-year storm.
H. Collection and holding facilities (e.g., tanks or basins) associated with run-on and run-off control systems must be emptied or otherwise managed expeditiously after storms to maintain design capacity of the system.
I. The owner or operator of a landfill containing hazardous waste which is subject to dispersal by wind must cover or otherwise manage the landfill so that wind dispersal of the hazardous waste is controlled.
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2180 et seq.