Louisiana Administrative Code
Title 33 - ENVIRONMENTAL QUALITY
Part V - Hazardous Wastes and Hazardous Materials
Subpart 1 - Department of Environmental Quality-Hazardous Waste
Chapter 43 - Interim Status
Subchapter J - Surface Impoundments
Section V-4462 - Design Requirements
Current through Register Vol. 50, No. 9, September 20, 2024
A. The owner or operator of each new surface impoundment unit, each lateral expansion of a surface impoundment unit, and each replacement of an existing surface impoundment unit must install two or more liners and a leachate collection and removal system between the liners and operate the leachate collection and removal system in accordance with LAC 33:V.2903.J, unless exempted under LAC 33:V.2903.C, K, or L.
B. The owner or operator of each unit referred to in Subsection A of this Section must notify the Office of Environmental Services at least 60 days prior to receiving waste. The owner or operator of each facility submitting notice must file a Part II application within six months of the receipt of such notice.
C. The owner or operator of any replacement surface impoundment unit is exempt from LAC 33:V.4462.A if:
D. The double liner requirement set forth in LAC 33:V.4462.A may be waived by the administrative authority for any monofill, if:
E. In the case of any unit in which the liner and leachate collection system has been installed pursuant to the requirements of LAC 33:V.4462.A and in good faith compliance with LAC 33:V.4462.A and with guidance documents governing liners and leachate collection systems under LAC 33:V.4462.A, no liner or leachate collection system which is different from that which was so installed pursuant to LAC 33:V.4462.A will be required for such unit by the administrative authority when issuing the first permit to such facility, except that the administrative authority will not be precluded from requiring installation of a new liner when the administrative authority has reason to believe that any liner installed pursuant to the requirements of LAC 33:V.4462.A is leaking.
F. A surface impoundment must maintain enough freeboard to prevent any overtopping of the dike by overfilling, wave action, or a storm. Except as provided in LAC 33:V.4462.B, there must be at least 2 feet (60 cm) of freeboard.
G. A freeboard level less than 2 feet (60 cm) may be maintained if the owner or operator obtains certification by a qualified engineer that alternate design features or operating plans will, to the best of his knowledge and opinion, prevent overtopping of the dike. The certification, along with a written identification of these alternate design features or operating plans which prevent overtopping, must be maintained at the facility.
H. Surface impoundments that are newly subject to RCRA Section 3005(j)(1) due to the promulgation of additional listings or characteristics for the identification of hazardous waste must be in compliance with LAC 33:V.4462.A, C, and D not later than 48 months after the promulgation of the additional listing or characteristic. This compliance period shall not be cut short as the result of the promulgation of land disposal prohibitions under LAC 33:V.Chapter 22 or the granting of an extension to the effective date of a prohibition in accordance with LAC 33:V.2239, within this 48-month period.
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2180 et seq.