Louisiana Administrative Code
Title 33 - ENVIRONMENTAL QUALITY
Part V - Hazardous Wastes and Hazardous Materials
Subpart 1 - Department of Environmental Quality-Hazardous Waste
Chapter 28 - Drip Pads
Section V-2807 - Inspections
Current through Register Vol. 50, No. 9, September 20, 2024
A. During construction or installation, liners and cover systems (e.g., membranes, sheets, or coatings) must be inspected for uniformity, damage, and imperfections (e.g., holes, cracks, thin spots, or foreign materials). Immediately after construction or installation, liners must be inspected and certified as meeting the requirements of LAC 33:V.2805 by an independent, qualified professional engineer. The certification must be maintained at the facility as part of the facility operating record. After installation, liners and covers must be inspected to ensure tight seams and joints and the absence of tears, punctures, or blisters.
B. While a drip pad is in operation, it must be inspected weekly and after storms to detect evidence of any of the following:
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2180 et seq.
NOTE: See LAC 33:V.2805.N for remedial action required if deterioration or leakage is detected.