Louisiana Administrative Code
Title 33 - ENVIRONMENTAL QUALITY
Part V - Hazardous Wastes and Hazardous Materials
Subpart 1 - Department of Environmental Quality-Hazardous Waste
Chapter 25 - Landfills
Section V-2503 - Design and Operating Requirements
Current through Register Vol. 50, No. 9, September 20, 2024
A. Any landfill that is not covered by LAC 33:V.2503.K or 4512.A must have a liner system for all portions of the landfill (except for existing portions of such landfill). The liner system must have:
B. Unless the permittee demonstrates to the administrative authority that the first permeable zone in which groundwater monitoring would occur is not a potable water aquifer, a leachate detection system shall be provided. A permanent barrier of at least 3 feet of recompacted clay with a permeability of 1 x 10-7 cm/sec or less shall be installed below the leachate detection system, which is located immediately under the liner system as required by LAC 33:V.2503.A unless an equivalent system is acceptable to the administrative authority.
C. The owner or operator of any replacement landfill unit is exempt from LAC 33:V.2503.L if:
D. The owner or operator must design, construct, operate, and maintain a run-on control system capable of preventing flow onto the active portion of the landfill during peak discharge from a 24-hour, 25-year storm.
E. The owner or operator must design, construct, operate, and maintain a run-off management system to collect and control at least the water volume resulting from a 24-hour, 25-year storm.
F. Collection and holding facilities (e.g., tanks or basins) associated with run-on and run-off control systems must be emptied or otherwise managed expeditiously after storms to maintain the design capacity of the system. Collected material must be disposed of properly.
G. If the landfill contains any particulate matter which may be subject to wind dispersal, the owner or operator must cover or otherwise manage the landfill to control wind dispersal. Wetting of the landfill for control of particulate matter is not allowed unless the landfill is equipped with a leachate collection system equivalent to LAC 33:V.2503.A.2.
H. The administrative authority will specify in the permit all design and operating practices that are necessary to ensure that the requirements of this Section are satisfied.
I. If noxious gases are generated, (or have the potential to be generated), the administrative authority may specifically require a gas collection and control system.
J. Accumulated rainfall and groundwater must be removed from the active portions of landfills in a timely manner.
K. Materials That May Be Landfilled
L. The owner or operator of each new landfill unit on which construction commenced after January 29, 1992, each lateral expansion of a landfill unit on which construction commenced after July 29, 1992, and each replacement of an existing landfill unit that was to commence reuse after July 29, 1992, must have installed two or more liners and a leachate collection and removal system above and between such liners. Construction commences is as defined in LAC 33:V.109.Existing Facilities.
M. The administrative authority may approve alternative design or operating practices to those specified in LAC 33:V.2503.L if the owner or operator demonstrates to the administrative authority that such design and operating practices, together with location characteristics:
N. The double liner requirements set forth in LAC 33:V.2503.L may be waived by the administrative authority for any monofill under the following circumstances:
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2180 et seq.