Louisiana Administrative Code
Title 33 - ENVIRONMENTAL QUALITY
Part V - Hazardous Wastes and Hazardous Materials
Subpart 1 - Department of Environmental Quality-Hazardous Waste
Chapter 17 - Air Emission Standards
Subchapter A - Process Vents
Section V-1707 - Standards: Process Vents
Current through Register Vol. 50, No. 9, September 20, 2024
A. The owner or operator of a facility with process vents associated with distillation, fractionation, thin-film evaporation, solvent extraction, or air or steam stripping operations managing hazardous wastes with organic concentrations of at least 10 ppmw shall either:
B. If the owner or operator installs a closed-vent system and control device to comply with the provisions of LAC 33:V.1707.A, the closed-vent system and control device must meet the requirements of LAC 33:V.1709.
C. Determinations of vent emissions and emission reductions or total organic compound concentrations achieved by add-on control devices may be based on engineering calculations or performance tests. If performance tests are used to determine vent emissions, emission reductions, or total organic compound concentrations achieved by add-on control devices, the performance tests must conform with the requirements of LAC 33:V.1711.C.
D. When an owner or operator and the administrative authority do not agree on determinations of vent emissions and/or emission reductions or total organic compound concentrations achieved by add-on control devices based on engineering calculations, the procedures in LAC 33:V.1711.C shall be used to resolve the disagreement.