Louisiana Administrative Code
Title 33 - ENVIRONMENTAL QUALITY
Part III - Air
Chapter 21 - Control of Emission of Organic Compounds
Subchapter N - Method 43-Capture Efficiency Test Procedures
Section III-2160 - Procedures
Universal Citation: LA Admin Code III-2160
Current through Register Vol. 50, No. 9, September 20, 2024
A. Except as provided in Subsection C of this Section, the regulations at 40 CFR 51, appendix M, July 1, 2021, are hereby incorporated by reference.
B. The volumes containing those federal regulations listed in Subsection A of this Section may be obtained from the Superintendent of Documents, United States Government Printing Office, Washington, DC 20402.
C. Modifications and Exceptions. The following modifications and exceptions are made to the incorporated federal standards.
1.
Method 204C, section 8.2 3.1. A sampling point shall be centrally located
outside of the temporary total enclosure (TTE) at four equivalent diameters
from each natural draft opening (NDO), if possible.
2. Other NDOs
a. This step is optional. Determine the
exhaust flow rate, including that of the control device, from the enclosure and
the intake air flow rate. If the exhaust flow rate divided by the intake air
flow rate is greater than 1.1, then all other NDOs are not considered to be
significant exhaust points.
b. If
the option above is not taken, identify all other NDOs and other potential
points through which fugitive emissions may escape the enclosure. Then use the
following criteria to determine whether flow rates and VOC concentrations need
to be measured.
i. Using the appropriate flow
direction indicator, determine the flow direction. An NDO with zero or inward
flow is not an exhaust point.
ii.
Measure the outward volumetric flow rate from the remainder of the NDOs. If the
collective flow rate is 2 percent, or less, of the flow rate from 40 CFR Part
51, Appendix M, Method 204E, Section 8.1 1, then these NDOs, except those
within two equivalent dia meters (based on NDO opening) from VOC sources, may
be considered to be nonexhaust points.
iii. If the percentage calculated in Clause
C.2.b.ii of this Section is greater than 2 percent, those NDOs (except those
within two equivalent diameters from VOC sources) whose volumetric flow rate
totals 2 percent of the flow rate from 40 CFR Part 51, Appendix M, Method 204E,
Section 8.1 1 may be considered as nonexhaust points. All remaining NDOs shall
be measured for volumetric flow rate and VOC concentrations during the capture
efficiency (CE) test.
iv. The
tester may choose to measure VOC concentrations at the forced exhaust points
and the NDOs. If the total VOC emissions from the NDOs are less than 2 percent
of the emissions from the forced draft and roof NDOs, then these NDOs may be
eliminated from further consideration.
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2054.
Disclaimer: These regulations may not be the most recent version. Louisiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google
Privacy Policy and
Terms of Service apply.