A. Buildings and Functions
Circle the Appropriate Answer |
|
1. Are classroom and laboratory facilities separated? |
Y N N/A |
2. Are classes being conducted in more than one part of the building at a time? |
Y N N/A |
3. Do classrooms, laboratories, offices, lavatories, and other facilities empty into a common interior hallway? |
Y N N/A |
4. Does the building have more than one level or floor? |
Y N N/A |
5. If the building is multi-level, is there more than one stairway leading to egress (exit) from the building? |
Y N N/A |
6. Are means of egress (exit) from the building clearly marked? |
Y N N/A |
7. In the event of loss of power to the building, is there battery-powered emergency lighting that will be turned on automatically? |
Y N N/A |
8. Are exit facilities inspected daily to make sure that all stairways, doors, and other exists are in proper working condition? |
Y N N/A |
9. Are all exit paths free and unobstructed? Note: Exit doors must not be locked, barred, or blocked in such a way as to prevent exit from the building. |
Y N N/A |
10. Are wedges or devices holding exit doors open prohibited? |
Y N N/A |
11. Are all fire escapes, stairs, passageways, doors, and windows free of obstructions that would interfere with the operation of the fire department? |
Y N N/A |
12. Are all fire doors tight fitting and in good operational condition? |
Y N N/A |
13. Are all classroom doors self closing? |
Y N N/A |
14. Are openings in the walls, floors, or ceilings that would contribute to the spread of fire from one room to another repaired? |
Y N N/A |
15. Is the vertical clearance between sprinklers and material below (such as head deflectors) at least 18 inches? |
Y N N/A |
16. Are accumulations of flammable or combustible waste materials and residues removed so that they will not contribute to a fire? Note: Examples of violations include open boxes of papers stored under the stairs and stored empty cardboard boxes. |
Y N N/A |
17. Is adequate clearance maintained between stored materials and light fixtures to prevent possible ignition? |
Y N N/A |
18. Is the clearance between stored materials and unit heaters, radiant space heaters, furnace ducts, and flues not less than 3 feet in all directions or in accordance with the clearances shown on the approval agency label? |
Y N N/A |
19. Are furnishings or decorations of an explosive or highly flammable character prohibited? |
Y N N/A |
20. Are decorative materials such as curtains, draperies, streamers, and fabrics flame resistant? |
Y N N/A |
21. Do teaching materials and children's artwork cover 20 percent or less of the wall area? |
Y N N/A |
B. Occupants
Circle the Appropriate Answer |
|
1. Are any of the occupants handicapped in anyway? |
Y N N/A |
2. Are there ever any individuals in the facility who are not part of the regular occupants of the buildings? |
Y N N/A |
3. Are there ever times when there are only one or two occupants in the building/ |
Y N N/A |
C. Applicable Codes
Circle the Appropriate Answer |
|
1. Have the NFPA Building, Life, Safety, and Electrical Codes been identified and consulted for applicability to this building and its purpose? |
Y N N/A |
2. Have municipality and school board safety codes been identified and consulted for applicability to this building and its purpose? |
Y N N/A |
3. Are all applicable codes being followed regarding the occupation use of this building? |
Y N N/A |
4. Are all applicable codes being followed regarding the installation, use and maintenance of equipment within the building? |
Y N N/A |
AUTHORITY NOTE: Promulgated in accordance with R.S. 17:6(A)(10).