Kentucky Administrative Regulations
Title 805 - ENERGY AND ENVIRONMENT CABINET
Chapter 4 - Division of Explosives and Blasting
Section 805 KAR 4:120 - Detonating cords
Universal Citation: 805 KY Admin Regs Service 4:120
Current through Register Vol. 51, No. 3, September 1, 2024
RELATES TO: KRS 351.350
NECESSITY, FUNCTION, AND CONFORMITY: KRS 351.335 requires the Department for Natural Resources to promulgate rules and administrative regulations concerning the manufacture, transportation, sale, storage, or use of explosives and unassembled components of explosives, and the maintenance of such explosives which has a direct bearing on safety to life and property. This administrative regulation effects the provisions of that law.
Section 1.
(1) The blaster shall select a detonating
cord consistent with the type and physical condition of the borehole and
stemming and the type of explosives used.
(2) Detonating cord shall be handled and used
with the same respect and care given other explosives.
(3) The line of detonating cord extending out
of a borehole or from a charge shall be cut from the supply spool before
loading the remainder of the borehole or placing additional charges.
(4) Detonating cords shall be handled and
used with care to avoid damaging or severing the cord during and after loading
and hooking-up.
(5) Detonating-cord
connections shall be competent and positive in accordance with approved and
recommended methods. Knot type or other cord-to-cord connections shall be made
only with detonating cords in which the explosive core is dry.
(6) All detonating-cord trunk lines and
branch lines shall be free of loops, sharp kinks, or angles that direct the
cord back toward the oncoming line of detonation.
(7) All detonating-cord connections shall be
inspected before firing the blast.
(8) When detonating-cord millisecond-delay
connectors or short-interval-delay electric blasting caps are used with
detonating cords, such use shall conform strictly with the manufacturer's
recommendations.
(9) When
connecting a blasting cap or an electric blasting cap to a detonating cord, the
cap shall be taped or otherwise attached securely along the side or the end of
the detonating cord, with the end of the cap containing the explosive charge
pointed in the direction in which the detonation is to proceed.
(10) Detonators for firing the trunk line
shall not be attached to the detonating cord until everything else is in
readiness for the blast.
(11) All
trunk lines of detonating cord shall be covered if located within 800 feet of
any public highway, dwelling house, public building, school, church, commercial
or institutional building.
(12)
When the use of detonating cord would cause severe concussion, the department
may cause all trunk lines to be covered by a minimum of six (6) inches of loose
earth.
STATUTORY AUTHORITY: KRS Chapter 13A, 351.335
Disclaimer: These regulations may not be the most recent version. Kentucky may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google
Privacy Policy and
Terms of Service apply.