Kentucky Administrative Regulations
Title 805 - ENERGY AND ENVIRONMENT CABINET
Chapter 4 - Division of Explosives and Blasting
Section 805 KAR 4:115 - Safety fuses
Universal Citation: 805 KY Admin Regs Service 4:115
Current through Register Vol. 51, No. 3, September 1, 2024
RELATES TO: KRS 351.350, 351.990
NECESSITY, FUNCTION, AND CONFORMITY: KRS 351.335 requires the Department for Natural Resources to promulgate rules and administrative regulations concerning the manufacture, transportation, sale, storage, or use of explosives and unassembled components of explosives, and the maintenance of such explosives which has a direct bearing on safety to life and property. This administrative regulation effects the provisions of that law.
Section 1. Use of Safety Fuses.
(1) The use of a fuse that has been hammered
or injured in any way shall be forbidden.
(2) The hanging of a fuse on nails or other
projections which will cause a sharp bend to be formed in the fuse is
prohibited.
(3) Before capping
safety fuse, a short length shall be cut from the end of the supply reel so as
to assure a fresh cut end in each blasting cap.
(4) Only a cap crimper of approved design
shall be used for attaching blasting caps to safety fuse. Crimpers shall be
kept in good repair and accessible to use.
(5) No unused cap or short capped fuse shall
be placed in any hole to be blasted; such unused detonators shall be removed
from the working place and destroyed. This prohibition shall not apply to
surface mining operations.
(6) No
fuse shall be capped or primer made up, in any magazine or near any possible
source of ignition.
(7) No one
shall be permitted to carry detonators or primers of any kind on his
person.
(8) The minimum length of
safety fuse to be used in blasting shall be as required by state law, but shall
not be less than thirty (30) inches.
(9) At least two (2) men shall be present
when multiple cap and fuse blasting is done by hand lighting methods.
(10) Not more than twelve (12) fuses shall be
lighted by each blaster when hand lighting devices are used. However, when two
(2) or more safety fuses in a group are lighted as one (1) by means of igniting
cord or other similar fuse lighting devices, they may be considered as one (1)
fuse.
(11) The so-called "drop
fuse" method of dropping or pushing a primer or any explosive with a lighted
fuse attached is forbidden.
(12)
Cap and fuse shall not be used for firing mud-cap charges unless charges are
separated sufficiently to prevent one (1) charge from dislodging other shots in
the blast.
(13) When blasting with
safety fuses consideration shall be given to the length and burning rate of the
fuse. Sufficient time, with a margin of safety, shall always be provided for
the blaster to reach a place of safety.
STATUTORY AUTHORITY: KRS 351.335
Disclaimer: These regulations may not be the most recent version. Kentucky may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google
Privacy Policy and
Terms of Service apply.