Kansas Administrative Regulations
Agency 5 - DEPARTMENT OF AGRICULTURE-DIVISION OF WATER RESOURCES
Article 1 - DEFINITIONS
Section 5-1-12 - List of water flowmeters certified by the manufacturer to meet the specifications of the chief engineer

Universal Citation: KS Admin Regs 5-1-12

Current through Register Vol. 43, No. 12, March 20, 2024

(a) A list of all makes and models of water flowmeters that have been certified by the water flowmeter manufacturer to meet the specifications of the chief engineer shall be maintained by the chief engineer. This list shall be made available by the chief engineer to the public upon request.

(b) A water flowmeter shall be placed on the list only if the manufacturer has submitted to the chief engineer all of the following information for each water flowmeter model:

(1) The water flowmeter manufacturer's name, address, contact person's name, and telephone number;

(2) the water flowmeter model name or number;

(3) proof that a random sample of water flowmeters of each model has been tested in accordance with the requirements of K.A.R. 5-1-4(a);

(4) the last date that the water flowmeter test equipment was tested and found to be accurate by standards traceable to the national institute of standards and technology (NIST);

(5) verification that the water flowmeter is designed and constructed so that accuracy will be maintained over the life of the water flowmeter;

(6) verification that the water flowmeter serial number and direction of flow are clearly indicated on the water flowmeter;

(7) verification that the register is weatherproof and sealed from all water sources;

(8) verification that the totalizer will read only in acre-feet, acre-inches, or gallons;

(9) the number of active digits in the totalizer;

(10) verification that the memory is nonvolatile;

(11) verification that the totalizer cannot be reset without breaking the manufacturer's seal or obtaining the authorization of the manufacturer, an authorized representative of the manufacturer, or the chief engineer;

(12) verification that the water flowmeter and register are constructed in such a manner that they can be sealed by the chief engineer;

(13) a description of the measuring chamber provided for each water flowmeter model;

(14) specifications of the flow-straightening vanes installed in the measuring chamber;

(15) the spacing recommendations for each water flowmeter model in terms of pipe diameters of straight pipe required upstream and downstream of the water flowmeter sensor; and

(16) the normal operating range of the water flowmeter.

(c) A brand or model of a water flowmeter shall be removed from the list of water flowmeters specified in subsection (a) of this regulation if it has been demonstrated to the chief engineer that the brand or model of water flowmeter does not reliably and consistently meet the accuracy standards of K.A.R. 5-1-9(a).

Disclaimer: These regulations may not be the most recent version. Kansas may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.