Current through Register Vol. 43, No. 39, September 26, 2024
(a) Definitions.
The following terms shall have the meanings provided below for the purposes of
this regulation.
(1) "Baker's percent" means,
for a given ingredient, the weight of that ingredient per 100 pounds of flour,
expressed as a percentage.
(2)
"Commercial bakery oven facility" means an establishment that is primarily
engaged in the manufacture, for sale at wholesale or retail, of fresh or frozen
bread, bread-type rolls, or dry bakery products, including biscuits, crackers,
or cookies, in which the products are made using yeast leavening.
(3) "Spike yeast" means any yeast added to
the dough beyond the initial yeast added to the dough.
(4) "Spiking time" means the elapsed time
between the addition of the spike yeast to the dough and the placement of the
dough into the oven.
(5) "Yeast
action time" means the elapsed time between the initial addition of the yeast
and the placement of the dough into the oven.
(b) Applicability. This regulation shall
apply to each new, modified, or existing commercial bakery oven facility that
meets these conditions:
(1) Is operating in
either Johnson or Wyandotte county, or both; and
(2) has bakery ovens with a total
potential-to-emit for volatile organic compounds (VOCs) equal to or greater
than 100 tons per year.
(c)
(1)
Determination of commercial bakery oven facility potential-to-emit. The owner
or operator of each commercial bakery oven facility operating in, or proposed
for construction or modification in, the area defined in paragraph (1) of
subsection (b) shall calculate the facility's total potential-to-emit (PTE) for
VOCs in tons per year, using either the following equation and the presumptions
in paragraph (2) of this subsection, or an EPA administrator-approved
alternative method if the use of that alternative method is approved in writing
by the department for this purpose:
PTEFacility (in tons/year) = Sum of PTEVOC for all ovens (in
tons/year)
Where: PTEVOC = PA * EFVOC (in pounds of VOC/ton of baked bread
* 1 ton/2000 pounds)
PA = maximum annual production rate for the yeast-leavened
finished bakery product (in tons/year)
EFVOC = VOC emission factor for the yeast-leavened finished
bakery product having the highest emission potential (in pounds of VOC/ton of
baked bread)
EFVOC = 0.95Yi + 0.195ti -0.51S -0.86ts + 1.90
Where: Yi = initial baker's percent of yeast to the nearest
tenth of a percent;
ti = total yeast action time in hours to the nearest tenth of
an hour;
S = final (spike) baker's percent of yeast to the nearest tenth
of a percent; and
ts = spiking time in hours to the nearest tenth of an hour.
(2) The owner or operator
shall presume for purposes of calculating the potential-to-emit that both of
the following conditions apply:
(A) Each
facility production line is operating 8,760 hours per year at maximum capacity.
(B) Each facility production line
is producing the product with the highest level of VOC emissions of those
products that it may produce.
(d) Control requirements. Each commercial
bakery oven facility subject to this regulation shall install and operate VOC
emissions control devices for each bakery oven to achieve at least an 80% total
removal efficiency on the combined VOC emissions of all baking ovens,
calculated as the capture efficiency times the control device efficiency.
(e) Time for compliance testing.
(1) The owner or operator of each existing
bakery oven facility subject to this regulation shall demonstrate compliance
with this regulation within one year from the effective date of this regulation
by testing in accordance with the methods and procedures specified in
subsection (f) of this regulation.
(2) Each new or modified bakery oven facility
subject to this regulation shall demonstrate compliance with this regulation
within 180 days of start-up by the testing of control equipment in accordance
with the methods and procedures specified in subsection (f) of this regulation.
(3) Additional testing of the
control equipment may be required by the department to demonstrate continued
compliance in accordance with the methods and procedures specified in
subsection (f) of this regulation.
(f) Testing requirements. The testing
required under subsection (e) of this regulation shall be conducted in
accordance with the following requirements:
(1) The testing shall be conducted at the
owner's or operator's expense.
(2)
The testing shall be conducted in accordance with a test plan submitted by the
owner or operator to the department and approved by the department before the
scheduled test date.
(3) The test
plan shall specify the following elements of the test:
(A) The name of the entity performing the
testing;
(B) the testing dates;
(C) the sampling location or
locations;
(D) the sampling
equipment to be used;
(E) the
sampling procedures to be followed;
(F) the sample recovery methods; and
(G) any other information
requested by the department pertaining to the facility and the test procedure.
(4) Testing procedures
shall be conducted in accordance with the following requirements:
(A) For the purpose of determining control
device efficiency, the owner or operator shall use USEPA test methods 18, 25,
or 25A at 40 C.F.R. Part 60, as adopted by reference in K.A.R. 28-19-720.
(B) For the purpose of determining
the capture efficiency of the air pollution control device, the owner or
operator shall use the methods specified by the USEPA's February 7, 1995
memorandum titled "revised capture efficiency guidance for control of volatile
organic compound emissions," and USEPA's technical document titled "guidelines
for determining capture efficiency," dated January 9, 1994, both of which
documents are hereby adopted by reference.
(C) Each owner or operator who demonstrates
that the bakery oven or ovens are totally enclosed and operate under negative
pressure with all venting through the air pollution control device may
preclude, upon approval by the department, the need for the capture efficiency
determination for those ovens so operated. The owner or operator seeking to
demonstrate that the ovens operate under negative pressure shall do so by using
the protocol titled "negative pressure enclosure qualitative test method for
bakery ovens," as approved by EPA by letter of March 20, 1997, which protocol
is hereby adopted by reference.
(D) Methods 204, 204A, 204B, 204C, 204D,
204E, and 204F of Appendix M of 40 C.F.R. Part 51, as in effect on July 1,
1999, are hereby adopted by reference.
(g) Compliance plan.
(1) Each owner or operator of an existing
commercial bakery oven facility subject to this regulation shall submit a
compliance plan to the department within three months of the effective date of
this regulation.
(2) The
compliance plan shall include the following information:
(A) The control device description;
(B) the testing methods and
procedures; and
(C) the operating
and maintenance plan for the control devices.
(3) The compliance plan shall identify the
steps and processes to be taken to assure that the facility is in compliance by
the date required for compliance.
(4) Each owner or operator of a new or
modified commercial bakery oven facility subject to this regulation shall
submit to the department an operation and maintenance plan for control devices
before start-up.
(h)
Monitoring and inspection.
(1) The owner or
operator of each commercial bakery oven facility subject to this regulation
shall continuously monitor and record data, as provided in paragraph (2) of
this subsection, for emissions control devices and for operational parameters
while the bakery oven is in operation.
(2) Each owner or operator required to
monitor under paragraph (1) of this subsection shall continuously monitor and
record the following parameters:
(A) The
exhaust temperatures of all combustion devices, if used;
(B) the temperature rise across a catalytic
oxidation bed, if used;
(C) the
exit stream temperature on all condensors, if used;
(D) the volumetric flow rate; and
(E) any other monitoring parameter that the
department may require the owner or operator to monitor.
(3) While operating the facility, the owner
or operator of the facility shall maintain the parameters listed in paragraphs
(2)(A) through (E) of this subsection within the baseline operational data
established during the initial compliance test.
(4)
(A) The
owner or operator shall inspect control devices and monitoring equipment to
assure that the control equipment is operating properly in accordance with the
operating and maintenance plan prepared under either paragraph (g)(2)(C) or
(g)(4) of this regulation, and that no leaks or malfunctions have occurred or
are occurring.
(B) Inspection
shall be made at the frequency defined by the equipment manufacturer, or as
otherwise appropriate for each unit, component, or operation, but not less than
monthly.
(C) The owner or operator
shall record the results of each inspection in a permanent log to be retained
on-site, and shall make the log available for inspection by a department
representative upon request.
(i) Recordkeeping.
(1) The owner or operator of each commercial
bakery oven facility subject to this regulation shall keep the records required
by this regulation on-site for at least five years following the date of
record.
(2) The owner or operator
of each commercial bakery facility shall make the records required by this
regulation available for inspection by a department representative upon
request.
(3) Daily records of the
following operational data shall be kept:
(A)
The amount of raw product processed;
(B) the baker's percent of yeast used;
(C) the fermentation time;
(D) the type of product baked;
(E) the amount of product baked;
(F) the monitoring and inspection
records specified in subsection (h) of this regulation; and
(G) any other information that the department
may determine to be necessary for determining that the facility is operated in
continuous compliance with this regulation.
(4) The owner or operator shall calculate
monthly emissions and shall record the emission factor used for each product,
including citation of the source of the emission factor and the results of the
calculations for the facility's ovens.