Kansas Administrative Regulations
Agency 28 - DEPARTMENT OF HEALTH AND ENVIRONMENT
Article 19 - AMBIENT AIR QUALITY STANDARDS AND AIR POLLUTION CONTROL
Section 28-19-18c - Methods for determining good engineering practice stack height
Current through Register Vol. 43, No. 39, September 26, 2024
(a) The minimum good engineering practice stack height value allowable for any source, regardless of size or location of any structures or terrain features, shall be 65 meters.
(b)
Hg = 2.5H
Hg = H + 1.5L
(c) A source may obtain good engineering practice stack height credit in excess of that calculated by K.A.R. 29-19-18c(b)(1)(A) or K.A.R. 28-19-18c(b)(1)(B) provided that it demonstrates by fluid modeling or a field study approved by the department that the emissions from a stack do not result in excessive concentrations of any air pollutant as a result of atmospheric downwash, wakes, or eddy effects created by the source itself, nearby structures or nearby terrain features.