Iowa Administrative Code
Agency 21 - Agriculture and Land Stewardship Department
Chapter 44 - On-site Containment of Pesticides, Fertilizers and Soil Conditioners
Rule 21-44.7 - Secondary Containment for Nonmobile Bulk Pesticide Storage and Mixing
Current through Register Vol. 47, No. 6, September 18, 2024
Base and walls of secondary containment facilities must be constructed of concrete, steel or other impervious materials which are Cornpatible with the pesticides being stored and will maintain their integrity under fire conditions. Storage containers must be anchored, as necessary, to prevent flotation or instability in the event of discharge into the secondary containment facility. Routine inspection is required to ensure against cracks or other conditions that may reduce the effectiveness of the containment facility. Cracks that occur in a secondary containment structure must be repaired with an acceptable sealant, and other repairs shall be made as needed to maintain the effectiveness of the containment facility.
The diked area shall not have a relief outlet and valve. The base shall slope to a collecting spot where precipitation water may be pumped out, provided the liquid is not contaminated with pesticides. If contaminated with a pesticide, the liquid shall be disposed of in accordance with applicable hazardous or solid waste requirements or field applied according to the pesticide label instructions.
(1) Storage in other than an enclosed structure.
(2) Storage in an enclosed structure.
(3) Precipitation must not be allowed to accumulate in the secondary containment facility. Failure to properly maintain secondary containment facilities may subject the firm to state and federal regulations related to hazardous waste generators.
(4) Discharges into a secondary containment facility must be promptly recovered to the maximum extent possible. Failure to properly manage discharge may subject the firm to pesticide misuse regulations and possibly to regulations related to hazardous waste generators.
(5) Pesticides shall be handled in a manner that minimizes the movement of pesticide dusts, aerosols and vapors from the pesticide storage and mixing site. The following dust control measures shall apply to bulk dry pesticide storage tanks:
(6) Discharge of pesticides from a secondary containment facility shall be recovered to the maximum extent possible. The Iowa department of natural resources, the county sheriff or local police shall be contacted as soon as possible, but not later than six hours of onset or discovery of spill.