Section 1.8-27 - Section 680.26(B)(2)(b); alternate means

Universal Citation: 675 IN Admin Code 1.8-27

Current through September 18, 2024

Authority: IC 22-13-2-2; IC 22-13-2-13

Affected: IC 22-12; IC 22-13; IC 22-14; IC 22-15; IC 36-7

Sec. 27.

(a) Delete the text of 680.26(B)(2)(b) and substitute to read as follows: Alternate means. Where structural reinforcing steel is not available or is encapsulated in a nonconductive compound, a copper grid shall be installed within concrete or under other surfaces in accordance with 680.26(B)(1)(b).

(b) After 680.26(B)(2)(b), insert an exception to read as follows: Exception to (b): The equipotential bonding grid shall not be required to be installed under pool decks of nonconductive materials.

Agency cited as 675 IAC 17-1.8-30, which was renumbered by the Publisher as 675 IAC 17-1.8-27.

Disclaimer: These regulations may not be the most recent version. Indiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.