Section 2-40 - Cleanouts
Current through September 18, 2024
Authority: IC 22-13-2-13
Affected: IC 22-12; IC 22-13; IC 22-14; IC 22-15
Sec. 40.
(a) Location of cleanout fittings shall be as follows:
(b) Cleanouts shall be accessible through an unobstructed minimum clearance of twelve inches (12") directly in front of the opening. Each cleanout fitting shall open in a direction opposite to the flow or at right angles to the pipe. Concealed cleanouts that are not provided with access covers shall be extended to a point above the floor or outside of the mobile structure, with pipe and fittings installed as required, for drainage piping without sags and pockets.
(c) Material. Plugs and caps shall be brass or approved or listed plastic, with screw pipe threads.
(d) Design. Cleanout plugs shall have raised heads except that plugs at floor level shall have counter-sunk slots.