Sec. 14.
When a structural assembly is subjected to total design live loads, the deflection for structural framing members shall not exceed the following:
Floor | L/240 |
Roof and Ceiling | L/180 |
Headers, Beams, Girders | L/180 (Vertical Loads Only) |
Where L = the clear span between supports or two times the length of a cantilever.
Disclaimer: These regulations may not be the most recent version. Indiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.