Sec. 6.

(a) Synthetic liners and installation plans shall be approved by the state chemist. The installation plan shall address proposed protection of the synthetic liner from mechanical damage, vandalism, wildlife, and deterioration from exposure to the sun according to the manufacturer's recommendations. A synthetic liner shall not be approved by the state chemist until the manufacturer of the liner provides a written confirmation of compatibility and estimate of the life of the liner.

(b) Synthetic liners shall have a minimum thickness of thirty (30) mils (eight-tenths (0.8) millimeters) and be chemically compatible with the materials being stored within the containment areas.

(c) Synthetic liners shall be installed under the supervision of a qualified representative of the manufacturer, and all field constructed seams shall be tested and repaired in accordance with the manufacturer's recommendations.

Disclaimer: These regulations may not be the most recent version. Indiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.