Indiana Administrative Code
Title 329 - SOLID WASTE MANAGEMENT DIVISION
Article 10 - SOLID WASTE LAND DISPOSAL FACILITIES
Rule 32 - Restricted Waste Site Type III and Construction/Demolition Sites; Additional Application Requirements to 329 IAC 10-11
Section 32-2 - Plot plans and cross-sectional drawings

Universal Citation: 329 IN Admin Code 32-2

Current through September 18, 2024

Authority: IC 13-14-8-7; IC 13-15-2-1; IC 13-19-3-1

Affected: IC 13-30-2; IC 36-9-30

Sec. 2.

(a) An application for a restricted waste site Type III or a construction/demolition site must be accompanied by plot plans using a scale of at least one (1) inch equals one hundred (100) feet for a site of less than eighty (80) acres, or a scale of at least one (1) inch equals two hundred (200) feet for a facility of eighty (80) acres or more. A bar scale must be shown on plans in order to properly indicate the scale if size changes occur. All plot plans must include the facility boundaries and indicate each of the required features set forth in this section within three hundred (300) feet of the facility boundaries. All facility plan elevations must correlate with United States Geological Survey (USGS) mean sea level data.

(b) An application for restricted waste site Type III must be accompanied by the following plot plans and cross sections:

(1) A plot plan that indicates the following:
(A) Locations and elevations of all existing and proposed on-site boring locations.

(B) Rock outcroppings.

(C) Surface water run-off direction.

(D) Fences.

(E) Utility easements and rights-of-way.

(F) Present land surface contours at intervals of no more than five (5) feet.

(G) Proposed location of scales required by 329 IAC 10-14-2.

(2) A plot plan that indicates the fill boundaries and proposed final contours of the site at intervals of no more than two (2) feet.

(c) An application for a construction/demolition site must be accompanied by the following plot plans and cross sections:

(1) A plot plan that indicates the following:
(A) Locations and elevations of all existing and proposed on-site boring locations.

(B) Rock outcroppings.

(C) Surface water run-off direction.

(D) Fences.

(E) Utility easements and rights-of-way.

(F) Present land surface contours at intervals of no more than five (5) feet.

(G) Proposed location of scales required by 329 IAC 10-14-2.

(2) A plot plan that indicates the fill boundaries and proposed final contours of the site at intervals of no more than two (2) feet.

(3) A plot plan, with surface contours at intervals of no more than five (5) feet, which indicates initial facility development. Compliance with this plan is a preoperational requirement under 329 IAC 10-35-2. Benchmarks as required by 329 IAC 10-35-2 must be shown with a description and elevation provided.

(4) A plot plan, with surface contours at intervals of no more than five (5) feet, which indicates the following:
(A) Land surface water diversion structures.

(B) Berms.

(C) Vegetation or fences for visual screening.

(D) Sedimentation control structures and erosion control structures.

(E) Protective barriers.

(F) Leachate collection and methane control systems if proposed.

(G) Existing and proposed structures.

(H) The precise location of the solid waste boundary.

(I) Methods of operation.

(J) Direction and the order operation and development will proceed.

(K) Depth of excavation.

(L) Length and width of trenches if proposed.

(M) Depth of lifts and size of working face.

(N) Areas of the site to be used only for acquisition of cover soil.

Disclaimer: These regulations may not be the most recent version. Indiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.