Sec. 5.
Except for lagoons, a storage structure for dewatered biosolid or industrial waste product must:
(1) have an impermeable base designed to support the stored dewatered biosolid or industrial waste product and the equipment utilized in handling the stored dewatered biosolid or industrial waste product;
(2) have leak-proof side walls at least three (3) feet in height or as otherwise approved by the commissioner;
(3) be designed and constructed to prevent contact with precipitation or to contain any contaminated storm water;
(4) be of such construction or design as to allow inspection and sampling of the contents;
(5) be constructed or designed to prevent nuisance conditions, safety hazards, or the harborage and breeding of vectors; and
(6) be constructed to prevent leaks and seepage and prevent spills that could enter surface waters or ground water.