Sec. 3.

(a) BP Products North America Inc., Source Identification Number 00003, shall comply with the sulfur dioxide emission limits in pounds per million British thermal units (MMBtu), pounds per hour, and other requirements as follows:

Emissions Unit Description Emission Limit lbs/MMBtu Emission Limit lbs/hour
(1) No. 1 Power Station Boilers 3, 4, 5, 6, and 7:
(A) Boilers 3 and 4 0.033 each 17.49 total
(B) Boilers 5, 6, and 7 0.033 each 26.24 total
(2) No. 3 Power Station Boilers 1, 2, 3, 4, and 6 0.033 each 18.98 each
(3) No. 11 Pipe Still:
(A) H-1X Heater 0.033 8.25
(B) H-2 Vacuum Heater 0.033 1.49
(C) H-3 Vacuum Heater 0.033 1.82
(D) H-101, 102, 103, and 104 Coker Preheaters 0.033 each 6.60 total
(E) H-200 Crude Charge 0.033 8.23
(F) H-300 Furnace 0.033 5.94
(4) No. 12 Pipe Still:

(A) H-1A, H-1B Preheaters, and H-2 Vacuum Heater 0.033 each 21.78 total
(B) H-1CN and H-1CS Crude Preheaters 0.033 each 7.92 total
(C) H-1CX 0.033 13.53
(5) No. 2 Isomerization H-1 Feed Heater Furnace 0.034 6.46
(6) No. 3 Ultraformer:
(A) H-1 Feed Heater Furnace 0.033 7.92
(B) H-2 Feed Heater Furnace 0.034 6.29
(C) F-7 Furnace 0.035 0.81
(7) No. 4 Ultraformer:
(A) F-1 Ultraformer Furnace, F-8A and F-8B Reboilers 0.033 each 13.00 total
(B) F-2 Preheat Furnace 0.033 9.44
(C) F-3 No. 1 Reheat Furnace 0.033 7.99
(D) F-4, F-5, and F-6 Reheat Furnaces 0.033 each 9.41 total
(E) F-7 Furnace 0.033 1.72
(8) Aromatic Recovery Unit F-200A and F-200B Furnace 0.035 each 17.47 total
(9) Blending Oil Desulfurization Furnace F-401 0.034 1.19
(10) Catalytic Refining Unit:
(A) F-101 Feed Preheater 0.04 2.88
(B) F-102a Stripper Reboiler 0.04 2.40
(11) FCU 500 750.00
(12) FCU 600 437.50
(13) Wastewater Sludge Fluid Bed Incinerator 1.78
(14) Catalytic Feed Hydrotreating Unit:
(A) F-801 A/B Preheater Furnace 0.035 2.33
(B) F-801 C Preheater Furnace 0.035 2.1
(15) Beavon-Stretford Tail Gas Unit 53.10 total reduced sulfur
(16) Sodium Bisulfite Tail Gas Unit 9.0
(17) Sulfur Recovery Unit Incinerator 0.033 1.25
(18) F-1 Asphalt Heater 0.033 0.43
(19) F-2 Steiglitz Park Residual Heater 0.033 0.90
(20) Distillate Desulfurization Unit Heaters WB-301 and WB-302 0.033 each 4.24 total
(21) Hydrogen Unit B-1 0.033 12.09

(b) BP Products North America Inc. shall:

(1) maintain daily records of:
(A) fuel type, average sulfur content, and average fuel gravity for each emissions unit specified in this section with sulfur dioxide emission limitations less than or equal to four-hundredths (0.04) pound per MMBtu;

(B) calculated coke burn and sulfur content of the coke for the FCU 500 and FCU 600;

(C) total reduced sulfur concentration, hydrogen sulfide concentration, and calculated stack gas flow rate for the Beavon-Stretford Tail Gas Unit; and

(D) sulfur dioxide concentration and stack gas flow rate for the Sodium Bisulfite Tail Gas Unit; and

(2) submit a report to the department within thirty (30) days after the end of each calendar quarter containing the average daily sulfur dioxide emission rate in pounds per hour sulfur dioxide for the emissions units specified in this section, except for the Beavon-Stretford Tail Gas Unit, that is to be reported as pounds per hour total reduced sulfur calculated as sulfur dioxide.

Disclaimer: These regulations may not be the most recent version. Indiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.