Indiana Administrative Code
Title 326 - AIR POLLUTION CONTROL DIVISION
Article 3 - MONITORING REQUIREMENTS
Rule 4 - General Provisions
Section 4-1 - Definitions

Universal Citation: 326 IN Admin Code 4-1

Current through March 20, 2024

Authority: IC 13-14-8; IC 13-17-3-4; IC 13-17-3-11

Affected: IC 13-11; IC 13-15; IC 13-17

Sec. 1.

In addition to the definitions provided in IC 13-11, 326 IAC 1-2, and 326 IAC 2-7, the following definitions apply throughout this article unless expressly stated otherwise:

(1) "Calendar quarter" means a consecutive three (3) month period (nonoverlapping) beginning on:

(A) January 1;

(B) April 1;

(C) July 1; or

(D) October 1.

(2) "Capture system" means the equipment, including hoods, ducts, fans, and booths, that is used to contain, capture, and transport a pollutant to a control device.

(3) "Continuous emission monitoring system" or "CEMS" means the equipment required by the applicable permit, state rule, or federal regulation used to sample, analyze, measure, and provide a continuous, permanent record of emissions in units of the applicable standard or other form.

(4) "Continuous opacity monitoring system" or "COMS" means the equipment required by the applicable permit, state rule, or federal regulation used to measure the opacity of the effluent on a continuous basis as either of the following:

(A) The optical density of the effluent gas.

(B) The opacity of the effluent gas.

(5) "Data" means the results of any type of monitoring or method, including the results of:

(A) instrumental or noninstrumental monitoring;

(B) emission calculations;

(C) manual sampling procedures;

(D) record keeping procedures; or

(E) any other form of information collection procedure used in connection with any type of monitoring or method.

(6) "Emission limitation or standard" means the following:

(A) Any applicable requirement contained in this title that constitutes:
(i) an emission limitation or standard;

(ii) a standard of performance; or

(iii) a means of emission limitation.

(B) An emission limitation or standard may be expressed:
(i) in terms of the pollutant, either as:
(AA) a specific quantity, rate, or concentration of emissions; or

(BB) the relationship of uncontrolled to controlled emissions; or

(ii) as either:
(AA) a work practice;

(BB) a process or control devices parameter; or

(CC) another form of specific:
(aa) design;

(bb) equipment;

(cc) operational; or

(dd) operation and maintenance;

requirement.

(C) For purposes of 326 IAC 3-8, an emission limitation or standard shall not include general operation requirements that an owner or operator may be required to meet.

(7) "Emission test", "compliance test", or "performance test" means a procedure for sampling a gas stream from a single sampling location at an emissions unit, or pollution control equipment, to determine a pollutant emission rate, concentration, or parameter while the emissions unit, or pollution control equipment is operating at conditions that result in measurement of the highest emission or parameter values (prior to any control device), or at other operating conditions approved by the department or U.S. EPA. A test shall comprise three (3) sampling runs for a specified sampling time span. Additional conditions may be required by applicable rules, permit, or order. The owner or operator shall perform the test using sampling and analytical procedures approved by the department or U.S. EPA for the specific pollutant or parameter and emissions unit, pollution control equipment, process, or operation.

(8) "Emissions unit" has the meaning set forth in 326 IAC 1-2-23.5.

(9) "Exceedance" means a condition that:

(A) is detected by monitoring that provides data in terms of an emission limitation or standard; and

(B) indicates that emissions (or opacity) are greater than the applicable emission limitation or standard (or less than the applicable standard in the case of a percent reduction requirement) consistent with any averaging period specified for averaging the results of the monitoring.

(10) "Malfunction" means any sudden, infrequent, and not reasonably preventable failure of air pollution control equipment, process equipment, or a process to operate in a normal or usual manner. Failures that are caused in part by poor maintenance or careless operation are not malfunctions. For purposes of this article, a CEMS or COMS is considered process equipment.

(11) "Monitoring" means any form of collecting data on a routine basis to determine or otherwise assess compliance with emission limitations or standards. The term includes the following:

(A) Record keeping, if records are used to determine or assess compliance with an emission limitation or standard, including:
(i) records of raw material content and usage;

(ii) records that document compliance with work practice requirements; or

(iii) other records used to determine or assess compliance with an emission limitation or standard.

(B) Compliance method tests that are conducted on a routine periodic basis.

(C) One (1) or more of the following data collection techniques, where appropriate, for a particular circumstance:
(i) Continuous emission or opacity monitoring systems.

(ii) Continuous process, capture system, control device, or other relevant parameter monitoring systems or procedures, including a PEMS.

(iii) Emission estimation and calculation procedures.

(iv) Maintenance and analysis of records of fuel or raw materials usage.

(v) Recording results of a program or protocol to conduct specific operation and maintenance procedures.

(vi) Verification of emissions, process parameters, capture system parameters, or control device parameters, using portable or in situ measurement devices.

(vii) Visible emission observations.

(viii) Any other form of measuring, recording, or verifying on a routine basis emissions, process parameters, capture system parameters, control device parameters, or other factors relevant to assessing compliance with an emission limitation or standard.

(12) "Out of control" means any data collected by a continuous monitoring system during periods immediately following an out of tolerance quality assurance assessment and prior to an acceptable quality assurance assessment.

(13) "Peaking unit" means an emissions unit that has:

(A) an average capacity factor of not more than ten and zero-tenths percent (10.0%) during the previous three (3) calendar years; and

(B) a capacity factor of not more than twenty and zero-tenths percent (20.0%) in each of those calendar years.

(14) "Predictive emission monitoring system" or "PEMS" means a system that uses process and other parameters as inputs to a computer program or other data reduction system to produce values in terms of the applicable emission limitation or standard.

(15) "QA operating quarter" means a calendar quarter in which there are at least one hundred sixty-eight (168) unit operating hours, as defined in subdivision (18), or, for a common stack or bypass stack, a calendar quarter in which there are at least one hundred sixty-eight (168) stack operating hours, as defined in subdivision (17).

(16) "Quality assurance" means those activities performed to establish validity of data used to demonstrate compliance.

(17) "Stack operating hour" means a clock hour during which flue gases flow through a particular stack or duct, either for the entire hour or for part of the hour, while any associated emissions units are combusting fuel.

(18) "Unit operating hour" means a clock hour during which an emissions unit combusts any fuel, either for part of the hour or for the entire hour.

Disclaimer: These regulations may not be the most recent version. Indiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.