Indiana Administrative Code
Title 326 - AIR POLLUTION CONTROL DIVISION
Article 10 - NITROGEN OXIDES RULES
Rule 5 - Nitrogen Oxide Reduction Program for Internal Combustion Engines (ICE)
Section 5-4 - Monitoring and testing requirements

Universal Citation: 326 IN Admin Code 5-4

Current through March 20, 2024

Authority: IC 13-14-8; IC 13-17-3-4; IC 13-17-3-11

Affected: IC 13-15; IC 13-17

Sec. 4.

Each affected engine subject to this rule shall comply with the following requirements:

(1) Complete an initial performance test consistent with the requirements of 40 CFR 60, Appendix A*, following installation of emission controls required to achieve the emission rate limit specified in section 3(b) of this rule.

(2) Perform periodic monitoring sufficient to yield reliable data from the relevant time period that is representative of a source's compliance with the emission rate limit specified in section 3(b) of this rule. Such periodic monitoring may include any of the following:

(A) Performance tests consistent with the requirements of:
(i) 40 CFR 60, Appendix A*; or

(ii) portable monitors using ASTM D6522-00*.

(B) A parametric monitoring program that specifies operating parameters, and their ranges, that will provide reasonable assurance that each affected engine's emissions are consistent with the requirements of section 3 of this rule.

(C) A predictive emissions measurement system that relies on automated data collection from instruments.

(D) A continuous emission monitoring system (CEMS) that complies with 40 CFR 60 * or 40 CFR 75 * as required under 326 IAC 3-5.

*These documents are incorporated by reference. Copies may be obtained from the Government Printing Office, 732 North Capitol Avenue NW, Washington, D.C. 20401 or are available for review and copying at the Indiana Department of Environmental Management, Office of Air Quality, Indiana Government Center-North, Tenth Floor, 100 North Senate Avenue, Indianapolis, Indiana 46204.

Disclaimer: These regulations may not be the most recent version. Indiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.