Indiana Administrative Code
Title 170 - INDIANA UTILITY REGULATORY COMMISSION
Article 5 - GAS UTILITIES
Rule 1 - Standards of Service
Section 1-6 - Customer meters; general requirements

Universal Citation: 170 IN Admin Code 1-6

Current through September 18, 2024

Authority: IC 8-1-1-3; IC 8-1-2-4

Affected: IC 8-1-2

Sec. 6.

(a) Whenever a meter is tested to determine the accuracy with which it has been registering in service, it may be considered correct if found not more than an average of two percent (2%), plus or minus, in error when tested at its check and open rates.

(b) For purpose of measurement to a customer, a cubic foot of gas is the amount of gas in a volume of one (1) cubic foot under the conditions existing in that customer's meter as and where installed, except:

(1) corrections may be made for temperature, pressure, and other nonstandard gas conditions as provided in the customer's contract; or

(2) the utility may, at its option, install gas meters which will compensate for changes in temperature above or below sixty degrees Fahrenheit (60° F).

(c) Each service meter of the displacement type must indicate clearly the cubic feet or other units of volume for which charge is made to the customer. Where gas is metered under high pressure or where the quantity is determined by calculation from recording devices, the utility shall, on request, supply the customer with the information to make clear the method by which the quantity is determined.

Disclaimer: These regulations may not be the most recent version. Indiana may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.